Download Print this page
American Dynamics RJ855AP Installation Manual
American Dynamics RJ855AP Installation Manual

American Dynamics RJ855AP Installation Manual

Sensornet 6-position junction box (j-box)

Advertisement

Quick Links

SensorNet 6-Position
1
Junction Box (J-Box)
This box provides power and data communications
for up to six SpeedDome or SpeedDome Ultra
camera domes. It also supports up to two outdoor
domes (one per group of ports, P1–3 or P4–6) or a
combination of up to one outdoor dome and three
indoor domes, with the following restriction: if
powering an outdoor dome, no other dome can be
plugged into the same group of connectors (P1–3
or P4–6).
IMPORTANT: Regulatory Requirements and
other declarations on page 4.
Figure 1. J-Box Components
B
A
F
E
G
A. Fuses
B. PC board (PCB)
C. Enclosure
D. Mounting Bracket
E.
Cover plate
F.
On/Off switch
8000-0975-01, Rev. F
D
C
I
H
J
K
G. Chassis
H. TB1 connector
I.
Knockouts
J.
Latch
K. TB2 connector
Installation Guide
Installation Requirements
WARNINGS
• NEVER PIERCE the enclosure.
• This installation should be made by qualified
service personnel and conform to the National
Electrical Code and applicable local codes.
• The product shall be located so as to provide
protection against unintentional operation by
employees, janitors and cleaners working
about the premises, by falling objects, by
customers, and by building vibration.
The installation must satisfy the following
requirements:
• Follow the SensorNet Network Guide section
to ensure proper network design.
• Minimize exposure to environmental extremes
by mounting the J-Box and the SpeedDome in
a sheltered area when possible.
• Always use dedicated, unswitched 24-hour AC
power, supplied in accordance with local codes
and with proper grounding.
• Ensure that the J-Box's power On/Off switch
and fuses are accessible.
• Always use the four mounting bolts for wall
and pole mount installations.
• Use the clamp package provided when
banding a camera dome to a pole.
Installation Process
Parts Required
Installation Kit (0351-0739-01) includes:
a) Anchor, toggle and bolt, 1/4x4
b) Anchor, wedge, bolt, 1/4x4
c) Screw, #10x1-1/24
d) Flat washer, wide, type B, #10
e) Conn, Plug Tublr, 1 x 4 Posn
f) Conn, Plug, Tublr 1 x 5 Posn
g) Grommet, Edge, Continuous
h) Bushing, STR RLF
4
2880-0040
4
2880-0052
4
2812-7816
4
2848-9306
6
2109-0254-03
6
2109-0254-04
1ft
3100-0029-01
1
3100-0035-11
1

Advertisement

loading

Summary of Contents for American Dynamics RJ855AP

  • Page 1 It also supports up to two outdoor • This installation should be made by qualified domes (one per group of ports, P1–3 or P4–6) or a combination of up to one outdoor dome and three service personnel and conform to the National indoor domes, with the following restriction: if Electrical Code and applicable local codes.
  • Page 2 Mounting the J-Box Connecting Power to the PC Board 1. Disconnect power to J-Box at circuit breaker. 2. Remove the four screws from the cover plate 1. Replace the four screws that secure the and remove the plate. chassis in the enclosure.
  • Page 3 2. Plug the compression connector into an available port (P1–P6) on the PCB. • FALSE CD is red for 0.5 sec if the device receives a false pulse (indicating noise on the 3. Wire the SensorNet data cable coming from the SensorNet cable).
  • Page 4 6A total. network of dealers. The dealer through whom you originally Do not parallel outputs. purchased this product is your point of contact if you have a For dry location. need for service or support. Our dealers are fully empowered to provide the very best in customer service and support.