114
Problem
One of the hard drives in
a mirrored (RAID 1) array
has failed.
A new drive with no
configuration is installed
into the bay which is
already part of a
mirrored (RAID 1) array.
A new drive with no
configuration is installed
into the bay which is
already part or not part
(is by itself) of a striped
(RAID 0) array.
Appendix B: SATA RAID configuration
Suggested solution
Replace the failed drive with another drive that
has the same or greater capacity.
Run the RAID configuration utility to configure
the new drive. Mark the drive as one of the
following:
• Failed - If the AutoRebuild option is disabled
in the CU.
• Rebuilding - If the AutoRebuild option is
enabled in the CU.
Run the RAID configuration utility to configure
the new drive.