Haier HSU-18HVA103/R2 - annexe 1 Safety Instructions

Haier HSU-18HVA103/R2 - annexe 1 Safety Instructions

Hide thumbs Also See for HSU-18HVA103/R2 - annexe 1:

Advertisement

Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that
goes out of use, please make sure it's inop-
erative and safe. Unplug the air conditioner
in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system
contains refrigerants, which require speciali-
zed waste disposal. The valuable materials
contained in an air conditioner can be recycled
.Contact your local waste disposal center for
proper disposal of an old air conditioner and
contact your local authority or your dealer if
you have any question. Please ensure that
the pipework of your air conditioner does not
get damagedprior to being picked up by the
relevant waste disposal center, and contribute
to environmental awareness by insisting on an
appropriate, anti-pollution method of disposal.
Disposal of the packaging of your
new air conditioner
All the packaging materials employed in the
package of your new air conditioner may be
disposed without any danger to the
environment.
The cardboard box may be broken or cut into
smaller pieces and given to a waste paper
disposal service. The wrapping bag made of
polyethylene and the polyethylene foam pads
contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to
a waste collecting center and used again after
adequate recycling.
Consult your local authorities for the name
and address of the waste materials collecting
centers and waste paper disposal services
nearest to your house.
HSU-18HA1(HVA1)03/R2(DB)
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide caref-
ully. The User's Guide contains very impor-
tant observations relating to the assembly,
operation and maintenance of the air
conditioner.
The manufacturer does not accept respon-
sibility for any damages that may arise due
to non-observation of the following
instruction.
Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
For the purpose of the safety,the air con-
ditioner must be properly grounded in acco-
rdance with specifications.
Always remember to unplug the air
conditioner before openning inlet grill. Never
unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and
pull straight out from the outlet.
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditioner.
Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or performating the air conditioner's tubes
with sharp or pointed items, crushing or
twisting any tubes, or scraping the coatings
off the surfaces. If the refrigerant spurts
out and gets into eyes, it may result in
serious eye injuries.
1
System Configuration
Domestic Air Conditioner

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-18HVA103/R2 - annexe 1

  • Page 1 Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully.
  • Page 2: Specifications

    3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is broken,change it with the type of T.25A/250V...
  • Page 3: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. CAUTION Do not install in the...
  • Page 4: System Configuration

    PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 5: Parts And Functions

    Vertical flap (adjust up and down air flow. Power plug Don't adjust it manually) Horizontal louver (adjust left and right air flow) For 22k unit, the power plug is on the outdoor unit Outdoor unit HSU-07HV03/R2(DB) HSU-22HV03/R2(DB) HSU-07HVA103/R2(DB) HSU-09HV03/R2(DB) HSU-22HVA103/R2(DB)
  • Page 6 Used for unit start and stop. displayed and this room temperature is only for reference. NOTE:Cooling only unit do not have functions and displays related with heating. Domestic Air Conditioner...
  • Page 7 If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key. Domestic Air Conditioner...
  • Page 8: Operation

    When indoor fan motor is running, it has healthy process function. (It's available under any mode) POWER/SOFT When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. BRIEF INTRODUCTION TO HEALTH ANION FUCTION...
  • Page 9: Auto Operation

    HEAT Then Select Auto operation On the displaying board,colorful displaying bar will be white. 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: POWER/SOFT Remote controller: AUTO Air conditioner is running under displayed fan speed.
  • Page 10: Cool Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 11: Dry Operation

    1 C,if kept depressed, it will decrease rapidly Select a desired temperature. 4.Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: AUTO Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp.setting+2...
  • Page 12: Fan Operation

    Press ON/OFF button, the unit stops. About FAN operation In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled. In FAN mode,SLEEP and POWER/SOFT operation is not available.
  • Page 13: Heat Operation

    Remote controller: AUTO Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
  • Page 14: Air Flow Direction Adjustment

    Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8 The horizontal louvers will swing according to the above positions. Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. Domestic Air Conditioner...
  • Page 15: Sleep Operation

    1 hours, temp. rises by 1 C further. another 3 hours, temp. rises by 1 The unit will run for further 6 hours then stops. further. The unit will run for further 3 Temp. is higher than temp. setting so that room hours then stops.
  • Page 16: Timer On/Off Operation

    After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
  • Page 17 " on the remote controller stops flashing. " " starts flashing. Time displayed: Unit starts or stops at x hour x min. 5.Time setting for TIMER OFF Just press HOUR button ,follow the same procedure in "Time setting for TIMER ON"...
  • Page 18: Power/Soft Operation

    To cancel POWER operation Press POWER/SOFT button twice ,POWER/SOFT disappears. SOFT Operation You can use this function when silence is needed for rest or reading. Selecting of SOFT operation Press POWER/SOFT button. Every time the button is pressed,display changes as follows:...
  • Page 19: Health Airflow Operation

    2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air cond- itioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.
  • Page 20: Emergency And Test Operation

    Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode. Domestic Air Conditioner...
  • Page 21: Maintenance

    During cooling operation prevent the penetration of direct sunlight with curtain or blind Use the louvers effectively If the unit is not to be used for a long time, turn off the power supply main switch. Domestic Air Conditioner...
  • Page 22: Air Filter Cleaning

    System Configuration Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance,be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral Do not use water, wipe the controller with a detergent diluted with water.Wring the water...
  • Page 23 The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun.
  • Page 24: Cleaning The Body

    To Keep Your Air conditioner in Good Condition after Season. Operate in cooling mode for 2-3 hours. To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30 C,cooling mode and High speed fan mode for 2-3 hours.
  • Page 25: Cleaning The Standard Air Filter

    Before Setting in High season Cleaning the standard air filter. Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation. Each of them are of different shapes. Connecting the earthing cable. Caution Incomplete earthing may cause an electric shock.
  • Page 26: Troubleshooting

    This noise is generated by the inspection casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated.

Table of Contents