N E W
New Models That Eliminate Worries about
Digital Sensor Setting Mistakes
Limited-function Models: Simple and Easy
■ One-key, one-operation concept for easy operation.
■ Threshold value setting with direct operation performed
while monitoring the detection status.
■ Lock function to prevent operating errors through
unintentional operation.
The Simplest Digital Fiber Sensor
Some people think that digital sensors with their advanced performance
are difficult to use, so we went back to the drawing board to rethink per-
formance and functions.
Without changing basic functions like APC and digital displays, OMRON
created a Digital Fiber Sensor that can be used as easily as the familiar
sensors with sensitivity adjustment knobs.
Incident level
Threshold value
KEY LOCK Switch
OPERATION MODE Selector
TEACH Key
Threshold Teaching
With/Without Workpiece: Teaching is performed in two states.
Automatic: Teaching is performed by passing a workpiece.
Technology
UP/DOWN Key
Threshold adjustment
Easy and Reliable Digital Sensors
with the Same Detection Performance
as Previous Models
Digital Fiber Sensors
E3X-DA@SE-S
The
Engine for High-performance
Sensing
OMRON's many years of accumulated sensing technology and high-
speed digital processing techniques merge to meet onsite needs.
Our goal is high-performance sensing that provides easy, reliable
application.
Reliable Detection of Small Workpieces
12-bit A/D converter (4,000 resolution)
Fine Sensing
Sensing Engine
Easy Operation
Easy-to-read Displays Even at a Distance
Intelligent Display
One Key, One Operation
Simple and easy direct operation
Consistent Emitter Power
Auto Power Control (APC)
High Performance

Advertisement

loading

Summary of Contents for Omron E3X-DA-SE-S

  • Page 1 Some people think that digital sensors with their advanced performance speed digital processing techniques merge to meet onsite needs. are difficult to use, so we went back to the drawing board to rethink per- Our goal is high-performance sensing that provides easy, reliable formance and functions.
  • Page 2 960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.) Control output Load power supply: 26.4 VDC max., Open-collector output, Load current: 50 mA max. (Residual voltage: 1 V max.) Protection circuits Power supply reverse polarity protection, Output short-circuit protection...

This manual is also suitable for:

E3x-da11se-sE3x-da41se-sE3x-da6se-sE3x-da8se-s