Connecting to the center module
The following instructions are for works to be conducted by qualified personnel. To prevent
electric shock, works relating to installation shall be conducted by qualified personnel.
Wiring to this product
● Use a shielded cable for the
Microphone.
● Remove the terminal cover from
the center module, then connect
this unit to the Lane A mic input
[OUT MIC] (Lane B mic input [OUT
MIC]: for WX-CC412BP only) as
follows.
Order post
Microphone
Speaker
(8 Ω)
WX-CC411BP / WX-CC412BP side
OUT MIC
G
COLD
HOT
WX-CM470P_PUQX1033ZAV1_OI_en.indd
Lane A / Lane B (WX-CC412BP only)
A Connect the Lane A mic input "HOT" wire to the
"HOT (Red)" wire of this unit.
B Connect the Lane A mic input "COLD" wire to the
"COLD (White)" wire of this unit.
C Connect the Lane A mic input "GND" wire to the
"GND (Black)" wire of this unit.
● Use soldering, crimping sleeves, etc. to connect securely.
GND
GND (shield cable)
17
WX-CC411BP / WX-CC412BP
A Connect HOT wires to each other
B Connect COLD wires to each other
C Connect GND wires to each other
GND (Black)
COLD
COLD (White)
HOT
HOT (Red)
WX-CM470P
17
2021/10/27
11:20:09