Transceiver and Cable Specifications

Component
Power Supply module
– 1400-W AC port-side exhaust (blue) (NXA-PAC-1400W-PE)
– 1400-W AC port-side intake (red) (NXA-PAC-1400W-PI)
– 2000-W HVAC/HVDC port intake (red) (NXA-PHV-2KW-PI)
– 2000-W DC port-side exhaust (blue) (NXA-PDC-2KW-PE)
– 2000-W DC port-side intake (red) (NXA-PDC-2KW-PI)
Transceiver and Cable Specifications
To see the transceiver specifications and installation information, see
interfaces-modules/transceiver-modules/products-device-support-tables-list.html.

Switch Power Input Requirements

The following table lists the typical amount of power that the switch consumes. It also lists the maximum
amount of power that you must provision for the switch and power supply for peak conditions.
Note
Some power supplies have capabilities that are greater than the maximum power requirements for a switch.
To determine the power consumption characteristics for the switch, use the typical and maximum requirements
that are listed in the following table.
Switch

Cisco Nexus 9364C-H1

Power Specifications

Power specifications include the specifications for each type of power supply module.
1400-W AC Power Supply Specifications
Property
Power
Cisco Nexus 9364C-H1 NX-OS Mode Switch Hardware Installation Guide
42
Typical Power
Consumption (AC or DC)
605 W
Specification
1400 W

System Specifications

Weight per Unit
2.64 lb (1.2 kg)
2.64 lb (1.2 kg)
2.42 lb (1.1 kg)
2.42 lb (1.1 kg)
2.42 lb (1.1 kg)
https://www.cisco.com/c/en/us/support/
Maximum Power
Heat Dissipation
Consumption (AC or
Requirement
DC)
1100 W
4248.116 BTUs
per hour
Quantity
4 (3 for operations
and 1 for
redundancy)