Electric connection (ONLY for UK)
WARNING:
THIS APPLIANCE MUST BE EARTHED
The mains lead of this appliance is fitted with a
BS 1363 5 amp fused plug.
To change a fuse in this type of plug use an
A.S.T.A. approved fuse to BS1362 type.
1. Remove the fuse cover and fuse .
2. Fit replacement 5A fuse into fuse cover.
3. Refit both into plug.
IMPORTANT: The fuse cover must be refitted
when changing a fuse and if the fuse cover is
lost the plug must not be used until a correct
replacement is fitted.
Correct replacements are identified by the
colour insert or the colour embossed in words
on the base of the plug.
Replacement fuse covers are available from
your local Electricity Board Shop.
HOW TO CONNECT AN ALTERNATIVE PLUG
If the fitted plug is not suitable for your socket
outlet, then it should be cut off and disposed of
in order to avoid a possible shock hazard
should it be inserted into a 5A socket elsewhere.
A suitable alternative plug of at least 5 Amp
rating e.g. 5 Amp round pin to BS 546 should
then be fitted to the cable.
The wires in this mains lead are coloured in
accordance with the following code:-
BLUE – "NEUTRAL" - "N"
BROWN – "LIVE" - "L"
GREEN AND YELLOW – "EARTH" - "E"
1 The GREEN AND YELLOW wire must be
connected to the terminal in the plug which
is marked with the letter "F" or by the Earth
symbol
or coloured green or green and
yellow.
2 The BLUE wire must be connected to the
terminal which is marked with the letter "N"
or coloured black.
3 The BROWN wire must be connected to the
terminal which is marked with the letter "L"
or coloured red.
GB
Systems available
Two systems are available:
Exhaust mode
Vapours are extracted outside through an
exhausting pipe that is affixed to the connection
ring above the hood.
Diameter of the exhausting pipe must be equal
to that of the connection ring.
In the horizontal runs the duct must be slightly
slanted (about 10°) and directed upwards to
vent the air easily from the room to the outside.
Attention!
If the hood is supplied with carbon filter,
then it must be removed.

Filter version

The air is filtered through a carbon filter (for its
installation see paragraph "Carbon filter") and
recirculated into the room.
Attention!
If the hood is not supplied with carbon filter,
then it must be ordered and mounted.
This version is used when there is no exhaust
duct for venting outdoors or when it is impossible
to install one.
Important:
For the 74,8 cm hood (Fig. 6-7)
Before using the hood, ensure that the inside
grids (G-Fig. 8)are open (Exhaust mode) or
closed (Filter version).