Mounting the hood body
• Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points.
• Hook the hood body onto the screws 12a.
• Fully tighten the support screws 12a.
• Adjust the screws Vr to level the hood body.

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Assemble the two halves of the hood body extension piece 14
• Push fit the assembled hood body extension piece 14 onto the
air outlet.
• Push fit connection 15 onto the hood body extension piece 14.
• Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
• Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets.
If this is not the case, adjust the position by either reversing the
connection extension pieces 14.1 or by cutting the hood body
extension 14 along one of the thinner section channels denot-
ing the prefixed lengths, then reassemble as described previ-
ously.
• Ensure that the activated charcoal filters have been inserted.
EN
Connections
Vr
12a
ø 150
ø 120
9
15
14.1
14
1
14
4