Before Calling For Service - LG DLEX7480LE.APBEUUS Owner's Manual

Table of Contents

Advertisement

Before Calling for Service

The dryer is equipped with an automatic error-monitoring system to detect and diagnose problems at an
early stage. If the dryer does not function properly or does not function at all, check the following before
you call for service.
Error Messages
Problem
Temperature sensor failure.
through
tE1
tE7
• Turn off the appliance and call for service.
Power cord is connected incorrectly.
Ps
• Check the connection of the power cord to the terminal block.
Exhaust system is too long or has too many turns/restrictions.
,
,
d8O
dGO
dGs
• Do not use the appliance until the exhaust system has been cleaned and/or repaired.
• Check the outside dryer vent while the appliance is operating to make sure there is strong
House exhaust system blocked.
• Keep the area around the dryer clean and free of clutter. Check vent hood for damage or
The display shows
More Time button was pressed.
bIGf
• This display indicates that the steam option has been set for a "big" item such as a
Operation
Problem
Appliance will not
Power cord is not properly plugged in.
turn on.
• Make sure that the power plug is securely plugged into a grounded outlet matching the
House fuse is blown, circuit breaker has tripped, or power outage has occurred.
• Reset circuit breaker or replace fuse. Do not increase fuse capacity. If the problem is a
Exhaust system is too long or has too many turns/restrictions.
Flow Sense (
W
)
indicator shows four
• Install a shorter or straighter duct run. See the Installation instructions for details.
bars during the
Partial blockage of the ductwork due to lint buildup or other foreign object.
drying cycle.
• Ductwork should be checked/cleaned immediately. The appliance can be used in this
The appliance has detected a restriction in the external dryer venting.
• If exhaust restrictions are sensed by the Flow Sense system, the indicator will remain on
Using the appliance with severely restricted exhaust is dangerous and could result in a fire
or other property damage.
airflow. If the exhaust system is extremly long, have it repaired or rerouted.
ling clogging. Make sure the area around the vent hood is clear.
comforter. Press the Less Time button to reduce the indicated load size.
appliance's rating plate.
circuit overload, have it corrected by a qualified electrician.
condition, but drying times will be longer and energy consumption will increase.
for 2 hours after the end of the cycle. Opening the door or pressing the Power button will
turn off the display.
Possible Cause & Solution
Possible Cause & Solution
TROUBLESHOOTING
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dl x748 e seriesDlgx7481le.apbeeus

Table of Contents