  • Page 1 Service Instructions Burnishers Maytag Services 16025783...
  • Page 4 Poly V Belt Drive floor. Floating Type Handle C5041 - machine resting with pad on floor. Dual - Lever Safety Switch 3. C5041 - adjust knob for proper pad pressure. Mechanical Switch Lock-Out Folding Handle Flexible Pad Driver Rigid Pad Driver Specifications:...
  • Page 5 Keep pad holder clean and always use a clean NOTE: Be sure the grounding washer is pad, changing pads frequently as they load up. positioned under one of the lower cover A motor overload condition could cause the built- screws when installing the cover. in circuit breaker to trip.
  • Page 6 F. Handle release Cable 1. Remove handle release lever. a. Remove mounting screw and eyelet bolt. NOTE: Do not over-tighten this bolt during reassembly. The cable must be able to pivot freely to avoid binding. Use this illustration for items C, D, E, and F. C.
  • Page 7 G. Cord / Strain relief 1. Remove restraint bar. 2. Remove switch bracket. 3. Disconnect attachment cord leads at switch, handle body and insulated terminal. 4. Remove strain relief. a. Hold inside nut while turning strain relief nut counterclockwise. Slide strain relief Handle release cable adjustment.
  • Page 8 I. Cam Plates To reassemble cam plates: 1. Remove shroud. 1. Position cam plate and brass washer on handle assembly. 2. Lower handle to lowest position. 2. Hold spacer with needle nose pliers and insert 3. Disconnect handle wiring at insulated into position while threading bolt through terminals near motor.
  • Page 9 L. Belt M. Pad driver sheave / bushing 1. Remove pad driver. 2. Loosen the motor mounting bolts or nuts. 3. Slide motor forward and remove belt. NOTE: On early models, it may be necessary to rotate the belt tensioner to allow the motor to slide.
  • Page 10 Ref. Point C5037 7/16 1. Loosen set screws in top and bottom race. C5039 7/16 C5041 2. Remove lock ring. * Slide bushing on shaft until it contacts lower bearing race. 3. Remove mounting bolts (4) and remove bearings. To reinstall pad driver sheave:...
  • Page 11 O. Front caster assembly (C5041) (caster 4. Continue to loosen adjustment knob until only) bracket assembly falls out of position. 1. Remove caster cover (2 screws). P. Motor assembly 2. Tap caster out of bracket. (Fig. 13) Disconnect unit from power supply before servicing motor.
  • Page 12 Set the distance from the main casting to the bottom of the pulley per specifications shown in Fig. 16. 2. Install the motor using four 3/8" lock nuts and 7. Remove motor mounting belts. 3/8" flat washers. Snug the nuts but do not completely tighten 8.
  • Page 13 Bad - 0 Ohms - meter deflects to 0 and stays. Bad - Inf. - No meter movement. S. Motor brushes - C5039, C5041 Locate under motor end bell. 9. Install the hood. Disconnect unit from power supply.
  • Page 14 Locate motor thrust washer and make sure it's in 2. Install end bell on motor - insure wave washer place upon reassembly. (Fig. 22) is in position. 3. Access brushes through motor openings and slide each brush into position against commutator.
  • Page 15 6. Motor failed; bad armature or 6. Check motor and replace. Check amp draw with bearings. belt disconnected. Readings should be approx. 4 amps for C5039 and C5041, and 8 amps for C5037. 7. Belt too tight. 7. Adjust belt and check.
  • Page 16 IV. Troubleshooting Check list - Commercial Burnishers The following is a guide to aid in determining the origin of a problem for which these models could conceivably be brought in for service. 7. Start capacitor bad (C5037). 7. Test - following guidelines in this instruction. 8.