Zhone TNE1544 Installation Instructions Manual
Zhone TNE1544 Installation Instructions Manual

Zhone TNE1544 Installation Instructions Manual

T1 network extenders

Advertisement

TNE1544 and TNE1584
T1 Network Extenders Installation Instructions
Document Number TNE1-A2-ZN14-30
May 2007
Contents
Software and Firmware License Agreement ..................................................... 2
Introduction to the TNE1544 and TNE1584 ...................................................... 4
Package Contents ............................................................................................. 4
Release Notes ................................................................................................... 4
Powering Up the Network Extender .................................................................. 5
Connecting the T1 Lines.................................................................................... 7
Connecting the Ethernet Lines .......................................................................... 8
LED Indicators ................................................................................................... 9
Web Interface .................................................................................................. 11
Command Line Interface ................................................................................. 15
Resetting the Network Extender to Factory Defaults ...................................... 16
Specifications .................................................................................................. 19
EMI Notices ..................................................................................................... 20
ACTA Customer Information ........................................................................... 20
Supplier's Declaration of Conformity ............................................................... 22
Notice to Users of the Canadian Telephone Network ..................................... 22
NEBS Compliance........................................................................................... 23
Important Safety Instructions........................................................................... 24
Product Documentation Online ....................................................................... 25
1

Advertisement

Table of Contents
loading

Summary of Contents for Zhone TNE1544

  • Page 1: Table Of Contents

    Document Number TNE1-A2-ZN14-30 May 2007 Contents Software and Firmware License Agreement ... 2 Introduction to the TNE1544 and TNE1584 ... 4 Package Contents ... 4 Release Notes ... 4 Powering Up the Network Extender ... 5 Connecting the T1 Lines... 7 Connecting the Ethernet Lines ...
  • Page 2: Software And Firmware License Agreement

    Zhone or its authorized distributor or reseller under the following terms and conditions: 1. Ownership: The Software is the sole property of Zhone and/or its licensors. The Licensee acquires no title, right or interest in the Software other than the license granted under this Agreement.
  • Page 3 5. Except for the Product warranty contained in the manual, the Software is provided “AS IS” and in its present state and condition and Zhone makes no other warranty whatsoever with respect to the Product purchased by you. THIS AGREEMENT...
  • Page 4: Introduction To The Tne1544 And Tne1584

    Introduction to the TNE1544 and TNE1584 Zhone's TNE1544 and TNE1584 are loop bonding network extenders for Zhone's 12000 and 4000 IP Broadband Loop Carriers that provide up to 6 Mbps (TNE1544) or 12 Mbps (TNE1584) of symmetrical bandwidth using T1 lines.
  • Page 5: Powering Up The Network Extender

    Powering Up the Network Extender The DC power terminal block on the network extender has five terminals: two positive, two negative, and one with no connection. Only one positive terminal and one negative terminal pair need be connected for operational purposes. The second positive and negative terminal pair may be connected to a backup DC power supply for redundancy.
  • Page 6 Power Connection – AC Power 1. The AC power supply is shipped with the power terminal strip already attached. No AC power supply other than the one supplied with the TNE15x4-x-US or TNE15x4-x-UK is approved for use in powering the unit. Using any other AC power supply could cause the unit to be non-compliant to emissions and safety regulations.
  • Page 7: Connecting The T1 Lines

    Multiple T1 lines also act as a backup should any of the lines become disabled. A network extender can only establish loop bonded connections with other Zhone equipment with the loop bonding feature. See Product to Product T1 Loop Bonding Compatibility (document number COMP-A2-GK43).
  • Page 8: Connecting The Ethernet Lines

    Single T1 Connection A single line connection can be established between a subscriber unit and any Zhone T1 provider unit, regardless of loop bonding capability. Likewise, a single line connection can also be established between a provider unit and any of Zhone's T1 subscriber units, regardless of loop bonding capability.
  • Page 9: Led Indicators

    LED Indicators Table 2. LEDs (1 of 2) State 10/100 Pulsing Ethernet Green Connections Solid Lnk/Act Green Illuminated 10/100 Solid Ethernet Amber Connections Duplex/ Illuminated Collision Pulsing Amber 10/100 Solid Ethernet Green Connections Illuminated Indication Standard operation Ethernet connection is established No Ethernet connection Full duplex Ethernet...
  • Page 10 Table 2. LEDs (2 of 2) State Flashing Connections Green* Lnk/Alm Solid Green (Ports 1–4 or 1–8) Solid Amber Pulsing Amber Flashing Connections Amber Tx (Ports 1– 4 or 1–8) Illuminated Flashing Connections Amber Rx (Ports 1– 4 or 1–8) Illuminated Power Solid Green...
  • Page 11: Web Interface

    Web Interface The network extender’s integral web management lets you configure and monitor the network extender using a standard web browser. To manage a Provider unit using web management, connect your PC to any Ethernet port of the Provider unit. By default, the Subscriber unit can be managed by the web management through its Ethernet ports, but you must first create a static entry for the unit in your PC’s ARP table in order to manage the unit through the T1 ports.
  • Page 12 Web Interface System Requirements Web Browser – Required for running web management. Compatible web browsers include, but are not limited to, Microsoft Internet Explorer (v4.0 or higher) and Netscape Navigator (v4.0 or higher). web management is optimized for use with Internet Explorer. Use your browser's default settings when running web management.
  • Page 13 192.168.254.251 (for a subscriber unit) into the Address field and press Enter. The web server opening screen appears. 10. Click on >> Next >>. The login dialog box appears. Log in using: Username: Password: The web management home page appears. The Subscriber unit is shown. superuser Password...
  • Page 14 From this screen you can: Click on . . . Management Config. Advanced Config. HTTP Password SNMP Config. SNMP Community Ethernet Connections Lnk/Act LEDs T1 Connections Lnk/Alm LEDs To configure . . . IP Address, Subnet Mask, Default Gateway, Inband Management VLAN ID and Priority. VLAN Flood Configuration and Membership System Name and Location, Management IP Address Filter, TFTP and Telnet access.
  • Page 15: Command Line Interface

    Command Line Interface The network extender can be managed with a Command Line Interface (CLI) through either a direct PC to COM (Communication) Port connection or from a remote network connection via Telnet. CLI System Requirements Straight-Through 8-Pin Modular Ethernet Cable – Required for establishing a direct connection from the COM port to a DB9 adapter.
  • Page 16: Resetting The Network Extender To Factory Defaults

    Refer to your terminal emulation program’s user manual for further information. Logging Into the CLI Once your terminal emulation program has been launched, device information is displayed, followed by a request for username and password. You must log in as a superuser in order to make configuration changes.
  • Page 17 Connector Pin Assignments T1 RJ48C Pin Assignments Table 3. T1 RJ48C Pin Assignments Function Pin 1 Rx Ring Pin 2 Rx Tip Pin 3 not used Pin 4 Tx Ring Pin 5 Tx Tip Pin 6 not used Pin 7 not used Pin 8 not used...
  • Page 18 DB9 to 8-Pin Modular Adapter Pinouts To connect the COM port to the DB9 serial port of a PC, use an adapter wired as shown: Table 5. DB9 to 8-Pin Modular Adapter Pinouts 8-Pin Modular Port Transmit Data Data Set Ready Receive Data Ground Data Terminal Ready...
  • Page 19: Specifications

    Weight Up to 1.5 Mbps per T1 port TNE1544: Up to 6 Mbps using loop bonded T1 circuits TNE1584: Up to 12 Mbps using loop bonded T1 circuits 1.25" (3.2 cm) High x 8.5" (21.6 cm) Wide x 4.75" (12.1 cm)
  • Page 20: Emi Notices

    The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Zhone Technologies, Inc.. If the equipment includes a ferrite choke or chokes, they must be installed per the installation instructions.
  • Page 21 Zhone worldwide office locations, use one of the following methods: Internet: Visit the Zhone World Wide Web site at www.Zhone.com. (Be sure to register your warranty at www.Zhone.com/warranty.) Telephone: Call our automated system to receive current information by fax or to speak with a company representative.
  • Page 22: Supplier's Declaration Of Conformity

    04 April 2007 Zhone Technologies, Inc., located at the above address, hereby certifies that the following models: TNE1584-X and TNE1544-X (X = P or S) bearing labeling identification number US:AW2DDNANTNE1584 complies with: the Federal Communications Commission's ("FCC") Rules and Regulations 47 CFR Part 68, and the Administrative Council on Terminal Attachments ("ACTA")-adopted technical...
  • Page 23: Nebs Compliance

    NEBS Compliance The equipment has been tested and found to comply with NEBS requirements as Telcordia document SR-3580 Issue 2, January 2005 for NEBS Level defined in , plus the amendments to this requirement made by Telecommunications Carrier Group in the following documents: Telecommunications Carrier Group NEBS Checklist SIT.NEBS.TE.NPI.2004.015, Issued April 4, 2006 (non-Carrier requirements only)
  • Page 24: Important Safety Instructions

    Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord. 3.
  • Page 25: Product Documentation Online

    Complete documentation for Zhone products is available at www.Zhone.com. Select Service & Support then select Documentation. To order a paper copy of a Zhone document, or to speak with a sales representative, please call (877) Zhone-20 (946-6320). Copyright 2007 Zhone Technologies, Inc.. Printed in U.S.A.
  • Page 26 *TNE1-A2-ZN14-30*...

This manual is also suitable for:

Tne1584

Table of Contents