D-SUB connector CN503

Repair the D-SUB connector:
1) Use a soldering iron and a de-soldering pump to remove as much solder as possible from the pin.
2) Lift the CN503 connector from the circuit board.
3) Place the new component on the circuit board. Be sure that it matches the circuit board footprint.
4) Solder the new component.