ECM F/A1000 Instruction Manual

Fuel-air ratio monitor

Advertisement

Quick Links

F/A1000 & F/A1500
Fuel-Air Ratio Monitor
Instruction Manual
02/06 Part Number 1001A-6

Advertisement

Table of Contents
loading

Summary of Contents for ECM F/A1000

  • Page 1 ™ ™ F/A1000 & F/A1500 Fuel-Air Ratio Monitor Instruction Manual 02/06 Part Number 1001A-6...
  • Page 2 No part of this manual may be photocopied or reproduced in any form without prior written consent from ECM: ENGINE CONTROL AND MONITORING. Information and specifications subject to change without notice. F/A1000 and F/A1500 are trademarks of ECM: ENGINE CONTROL AND MONITORING. Printed in the United States of America.
  • Page 3: Table Of Contents

    Table of Contents Introduction The Fuel-Air Ratio Monitor F/A Monitor Components List Important Operation Notes How to Use Hooking-up the F/A Monitor Power Warm-up Analog Output SMB Interface (Serial Measurement Bus, F/A1500 Only) Simulated O Sensor (EGO) Output Calibration Fuel Type Compensation Pressure Compensation Specifications and Limits Measurement Range and Accuracy...
  • Page 4 Supplementary Information...
  • Page 5: Introduction

    Introduction The Fuel-Air Ratio Monitor The ECM Fuel-Air Ratio Monitor (F/A Monitor) was designed for the professional calibration of fuel-injection or carburetor systems. Using a wide-range UEGO (Universal Exhaust Gas Oxygen) sensor, the F/A Monitor provides unmatched measurement range, accuracy, and speed-of-response in a compact, lightweight package.
  • Page 6: Important Operation Notes

    Important Operation Notes 1. Before installing the UEGO sensor, apply a small amount of non-lead containing antiseize compound to its threads. Do not get the compound on the sensor's tip. 2. Do not operate an engine for more than three minutes with the UEGO sensor in the exhaust and the control module’s power off.
  • Page 7: How To Use

    How to Use Hooking-up the F/A Monitor Location of the UEGO Sensor The UEGO sensor should be located from 12" to 48” from the exhaust valve(s) of the engine. A location further from the engine may be used as long as it is at least ten times the exhaust pipe diameter upstream of the end of the exhaust system.
  • Page 8: Power

    The F/A Monitor has a 0V to 5V linearized output suitable for input into a data acquisition or engine control system. The analog output is available from the female BNC connector on the wiring harness. For the F/A1000 only, the shell of the connector is signal ground and it is electrically connected to the power source ground.
  • Page 9: Smb Interface (Serial Measurement Bus, F/A1500 Only)

    SMB Interface (Serial Measurement Bus, F/A1500 Only) The F/A1500 has a SMB interface allowing serial communication with as many as 16 F/A1500 modules using a single RS-232 type serial port from a computer. Using the SMB interface, AFR, F/A, Lambda, %O , and module status can be read from each F/A1500 module.
  • Page 10 COMMAND DESCRIPTION RANGE FORMULA See Command Mode and Device Enter Command Mode Identification sections 8 bit λ 0.744 to 1.235 λ = (Data Byte + 186)/250 16 bit λ High Byte 0.549 to 1.235 λ = (High Byte*256 + Low Byte)/1000 16 bit λ...
  • Page 11: Simulated O 2 Sensor (Ego) Output

    1st BYTE 2nd BYTE COMMAND NO. COMMAND XXXX 0000 XXXX 0000 Stay in Command Mode XXXX 0000 XXXX 0001 Device Identification (See Below) XXXX 0000 XXXX 0010 Not Used …. …. …. …. XXXX 0000 XXXX 1111 Exit Command Mode Device Identification In response to the DEVICE IDENTIFICATION command, the module sends back 6 bytes (including a check sum): 0x00, 0x00, 0x02, 0x18, 0x18, 0x0C, 0x00, 0xDA.
  • Page 12: Calibration

    Calibration Calibration of the F/A Monitor and the UEGO sensor can be easily performed using air. To bring the system into calibration, put the sensor in air and adjust the calibration potentiometer (CAL POT) on the control module using the calibration screwdriver provided. First turn the potentiometer counter-clockwise until the CAL LED (yellow) is off, then turn the potentiometer slowly clockwise until the CAL LED just lights.
  • Page 13 Pressure Compensation Equation for F/A F/A(corrected) = (F/A(measured) + aP) / (1 + bP) [Equation 3a] where: F/A(corrected) = the F/A corrected for exhaust pressure. F/A(measured) = the F/A output by the F/A. a = 4.30x10 for F/A > 0.0686 (rich). a = 5.70x10 for F/A ≤...
  • Page 14: Specifications And Limits

    Specifications and Limits Measurement Range and Accuracy Range: 0.055 to 0.125 F/A (gasoline) (Analog Output and SMB) 8.0 to 18.0 AFR, 0.549 to 1.235 Lambda, 0.0 to 4.0 %O (SMB Only) Accuracy: 1.5% Exhaust Operating Limits Maximum Exhaust Gas Temperature: 950 deg. C, 1742 deg. F. Exhaust Gas Pressure Range: 0.8 - 1.7 atm (gauge).
  • Page 15: General Information

    SMB Interface (Serial Measurement Bus, F/A1500 Only): • AFR, F/A, Lambda, %O2, and Module Status Output • Each Module can be assigned an address from 0h to Fh using a switch on the side of the module • Auto-detect feature for Device Identification •...
  • Page 16: Troubleshooting

    Keeping the control module and its wiring harness away from the engine's ignition wires will help avoid this source of electrical noise. 2. For the F/A1000 only, the ground wire on the wiring harness is not attached directly to the ground at the vehicle’s battery. If you connect a single wire from the wiring harness ground to the vehicle’s battery, a large voltage drop will occur...
  • Page 17: Safety Warnings

    Safety Warnings In installation and use of this product, comply with the National Electrical Code and any other applicable Federal, State, or local safety codes. Always wear eye protection when working near engines, vehicles, or machinery. During installation, turn off the power and the engine and take all other necessary precautions to prevent injury, property loss, and equipment damage.
  • Page 18: Warranty And Disclaimers

    Warranty and Disclaimers WARRANTY The products described in this manual, with the exception of the UEGO sensor, are warranted to be free from defects in material and workmanship for a period of one year from the date of shipment to the buyer. Within the one year warranty period, we shall at our option replace such items or reimburse the customer the original price of such items which are returned to us with shipping charges prepaid and which are determined by us to be defective.
  • Page 23 State Diagram for SMB Communication...
  • Page 26 Los Altos, CA 94023-0040 • USA • (408) 734-3433 • Fax: (408) 734-3432 www.ecm-co.com...