Sharp CD-MPS660H Service Manual page 2

Hide thumbs Also See for CD-MPS660H:
Table of Contents

Advertisement

CD-MPS660H/CD-MPS660E
SAFETY PRECAUTION FOR SERVICE MANUAL
Precaution to be taken when replacing and servicing the Laser Pickup.
The AEL (Accessible Emission Level) of Laser Power Output for this model is specified to be lower than Class 1 Requirements.
However, the following precautions must be observed during servicing to protect your eyes against exposure to the Laser beam.
(1) When the cabinet has been removed, the power is turned on without a compact disc, and the Pickup is on a position outer than
the lead-in position, the Laser will light for several seconds to detect a disc. Do not look into the Pickup Lens.
(2) The Laser Power Output of the Pickup inside the unit and replacement service parts have already been adjusted prior to shipping.
(3) No adjustment to the Laser Power should be attempted when replacing or servicing the Pickup.
(4) Under no circumstances look directly into the Pickup Lens at any time.
(5) CAUTION - Use of controls or adjustments, or performance of procedures other than those specified herein may result in
hazardous radiation exposure.
IMPORTANT SERVICE NOTES (FOR U.K. ONLY)
Before returning the unit to the customer after completion of a
repair or adjustment it is necessary for the following withstand
voltage test to be applied to ensure the unit is safe for the
customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
Withstanding Voltage Tester
Test voltage
Set time
Set current (Cutoff current)
Unit
Judgment
OK: The "GOOD" lamp lights.
NG: The "NG" lamp lights and the buzzer sounds.
set value
4,240 VPEAK
3,000 VRMS
6 secs
4 mA
– i –
WITHSTANDING
VOLTAGE TESTER
AC
OUT
SHORT-CIRCUIT
AC POWER
SUPPLY CORD
PROBE
UNIT
CONNECT THE PROBE
TO GND OF CHASSIS
SCREW

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cd-mps660eCp-mps660hCp-mps660e

Table of Contents