IBM 129 Reference Manual page 27

Card data recorder
Hide thumbs Also See for 129:
Table of Contents

Advertisement

Function
Punch
Code
Field
Location
Standard
Codes
Field Definition (FD)
12
All
columns, except
first
column
Auto
Skip
Field
11
First
column
Auto Dup/Auto Ver
Field
First
column
Alpha
Shift
(Programmed)
1
Each column
for
alpha
shift
Left-zero Control Field (Verify
Only)
3
First
and
last
columns
Special Feature
Codes
Self-check
Field
2
First
and
last
columns
Add
Accumulator
A
5
First
column
Add
Accumulator
B
6
First
column
Add
Accumulator
C
7
First
column
Punch Accumulator
A,
B,
or
C
4
+
(5
or
6
or 7)
First
column
Punch and
Reset
Accumulator A,
B, or
C
4
+
8+(5or6or7)
First
column
Direct
Punch
Control
for
"Buffered"
Field
3
First
column
for
direct
punch
mode
only
Verify
Read
Control to Stop Verify
Read
Operati
on
11-0
Column
desired
to
stop
card
1
.
Program codes apply
in
program
levels
1-6.
Program
level
is
80
single-position
fields,
alpha
shift.
2.
If
LZ
control
in
units position verify
is
not
desired,
do
not
use
3-punch
in
units position.
3.
Only
field
definition
is
required
for
LZ
punching.
Program
cards
coded
for
LZ
in
verify
mode
(3-punches)
may
be
used
in
punch
mode
without
alteration
because
machine
ignores
3-
codes
in
punch
mode,
unless direct
punch
control feature
is
used
(see chart)
4.
Minimum
field
size
is
two
columns
for
accumulate,
self
check,
and LZ.
5.
Maximum
field
size
is
79
columns
for
self
check and
LZ.
6.
Maximum
input
field
size
for
accumulate
is
14 columns;
maximum
punchout
field size
is
19 columns.
7.
A
field
may
be programmed
to
add
into
any
or
all
accum-
ulators;
punchout
is
limited
to
one
accumulator
per
field.
8.
Self-check
fields
may
be
adjacent.
Self-check and accumulate
operate
in
both
punch and
verify
mode.
However,
self-check
cannot be
programmed
in
the
same
field
as
accumulate
or
left
zero.
9.
Verify read control
(1
1-0 code) must not
be programmed
in
same column
as
auto skip
(11)
or
auto
dup
(0)
codes,
nor
in
any
self-check
programmed
field.
10.
Programs remain
in
storage
until
another program
is
read
in
to
replace the
original
program,
or
until
mainline
switch
is
turned
off.
This
resets
programs
1-6
to
blanks (equivalent
to
80
single- position
fields,
numeric
shift).
Figure
5.
Program Codes
Field
12(&)
Auto
Skip 11(->
Dup
Alpha
!PD
1
I
3
1
1
=>
E
oZ
77
J
818
999
i
i
3
onnD
ooooo
liin
11111
D
Q.
E
•-
7
77 77
88898
9
9999
(Sill
nnnnn
QUMTirr
010
9
io
n|i2
13
i
1
1
1|1
1
'
o
E
c
=
OZ
I
7 7
717 7
|w
I
8IB8I
I
nnnnncccDDDnccccE
COMMODITY
DDDD
p
oiscniPTWii
\m
ooooooooooooooooo
p
I
to
IT 18 13
70
71
71
2]
74
»
76*77
21 79 10
3)
17
31
BnDnCCCCDIlCCDCBCC
22222222222 222222
3 3 3 3
3 3
3
3 3
3
3 3 3 3 3 3
3
34 35 36
1731
1940
41
4214344
154647
484*50
51
Manual
Field
Alpha
bet
ic
555555555
55
555555
"165666666666668866
77777777777777777
888988888
88
888888
9 9 919
9
9fj|
99899999999999999
9
10
ll|l?
13
ullSliB
17 18
19
20
71
22
73
74
75
76 77
702*
30
31
33
33
00
1
00
1
5
£
OZ
77
99
onorjD
PRICE
010
1
1
1111
L
2
o E
c
=>
oZ
Dooorjc
Doncnrj
dddde dddd
sues
JMHMMT
0000
0100
52 53
54
55 56157
58
59
60
61
62
S3
64 65 66
67
68
1
1
1
1
nn
i
2
5
E
oZ
I
I
77
7
717
7
I
88
8
8188
I
99
99199
394C
41 42143
4414546 47 41
45750
51
77 77
7177
I
88888188
I
99
9
9919
9
O0
00I00
1
1
1
1
111
I
2
S E
oZ
5
1
777
77177
1
B
88
88188
I
9 9 9 9
9i9 9
57
53
54
55SU57S8I
Do
00
1
00
a
o
11 11
1
22222
Q333D
IHOICE
m.
00000
DDDDDDDDD
D
77771
89881
9
9
9 9
5=
G162tej»4l65
66»7
6fl5l
^
000000000
I
77
73 74 75
76 77
78
7980
111111111
222222222
»M
3
3
33
3
333
"•A
u
t
om
a
t
i
i
d
Skip
555555555
66E666S66
777777777
886618888
999999999
77
73
74
1*.
la
11 IS 7;
3.1
Figure
6.
Program
Card,
Program
Levels
1-6
24

Advertisement

Table of Contents
loading

Table of Contents