SAFETY
CHECK-OUT
(US Model)
After
correcting
the
original
service
problem,
perform the following safety check before releasing
the set to the customer:
LEAKAGE
TEST
The AC leakage from any exposed metal part to
earth ground and from all exposed metal parts to any
exposed metal part having a return to chassis, must
not
exceed
0.5mA
(500
microampers).
Leakage
current
can
be
measured
by
any
one
of
three
methods.
1.
A
commercial
leakage
tester,
such
as
the
Simpson
229
or RCA
WT-540A.
Follow the
manufacturers' instructions to use these instru-
ments.
2.
A battery-operated AC milliammeter.
The Data
Precision
245 digital multimeter is suitable for
this job.
3.
Measuring the voltage drop across a resistor by
means
of a VOM
or battery-operated
AC volt-
meter.
The
"limit"
indication
is 0.75 V, so
analog
meters
must
have
an
accurate
low-
voltage
scale.
The
Simpson
250
and
Sanwa
SH-63Trd
are examples of a passive VOM
that
is suitable.
Nearly all battery operated
digital
multimeters
that
have
a
2V
AC
range
are
suitable.
(See Fig. A)
To Exposed Metal
Parts on Set
|
AC
0.15 uF
1.5kKDL
voltmeter
{0.78 V}
Earth Ground
TA-AX500