13.4. Check
13.4.1. Setting Procedure
13.4.1.1. Setting JIG
(1) Connect UTC-1000 Equipment to JIG device as a like left
picture
- Connection Line:
UTC-1000 TOP1<- ->Game port(RJ21)
-> TV-LINK CFG (Phone Jack)
UTC-1000 TOP2<- ->JIG 11pin Connection
UTC-1000 RF1<- ->b_LAN RF IN
UTC-1000 LAN<- ->PC LAN Port
13.4.1.2. Working procedure
(1) Connection
UTC-1000 LAN <- -> PC LAN Port
UTC-1000 TOP1 <- -> Game port(RJ21)
-> TV-LINK CFG (Phone Jack)
UTC-1000 RF1 <- -> b_LAN RF IN
(2) Power on JIG : Switch on front of the JIG
(3) Test Start
UTC-1000 TOP2 <- -> JIG 11pin Connection
(4) Checking b-LAN MAC Address
Check whether it is same their address numbers or not
between B-LAN Label and on the pc address numbers.
● Checking JIG contents
(1) Check whether displaying all "Pass" or not at the number
3.4.6.7.9 contents of UTC-1000 on the PC
(2) Check "Version 6.0" of the 1. b_LAN Application version
(3) Check whether it is same their address numbers or not
between B-LAN Label and
(4) MAC Address on the pc.
14. Serial number download
Connect Bar Code scan equipment and TV set by RS-232C cable
(1) E2PROM Data Write
(2) E2PROM Data Read
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
15. MPI Check
[Only for XXLD620H series]
1) Commercial JIG Setting
(1) Connect 5V Adaptor
(2) Change Adaptor Mode
(3) Setting Mode Switch
[ 7/8 pin up , another pin down]
※ Caution : Connector direction
2) Commercial JIG setting (sub Jig board)
(1) Connect 5V Adaptor
(2) Change tact switch direction [right]
(3) Connect 11 Pin Connector
(4) Connect MPI Jack ( using Direct R12 Cable)
※ Caution : Connector direction / position
3) MPI test method
(1) Connect MPI cable to mainboard
(2) Conform test result
OK : 4. MPI TEST : OK
NG : 4. MPI TEST : NG
(3) Disconnect MPI cable
- 17 -
LGE Internal Use Only

Advertisement