Fitting The Additional Handle; Fitting/Changing The Roughing/Cutting Disc - Parkside PWSA 20-Li B2 Instructions Manual

Cordless angle grinder
Hide thumbs Also See for PWSA 20-Li B2:
Table of Contents

Advertisement

Available languages

Available languages

RISK OF INJURY
Make sure that the blade guard
at least at the same angle as the additional
handle
(see fig. B). Otherwise, you could
cut injure yourself on the roughing disc or
cutting disc.
Open the clamping lever
Place the blade guard
in the coding groove
Turn the blade guard
(working position). The closed side of the blade
guard
must always be toward the operator.
Close the clamping lever
guard
into position. If necessary, the clamp-
ing force of the lock can be changed by loos-
ening or tightening the adjusting nut
that the blade guard
of the spindle.

Fitting the additional handle

CAUTION!
For safety reasons, this appliance may only
be used with the additional handle
to do so can lead to serious injury. The
additional handle
the left, the right or the top, depending on the
job at hand.
Fitting/changing the roughing/
cutting disc
Always wear protective gloves when changing
cutting/rough grinding discs.
Pay attention to the dimensions of the roughing/
cutting disc. The diameter of the hole must fit the
mounting flange
without any play. Do not use
a reducer or adapter.
NOTE
Use only discs which are free of dirt.
PWSA 20-Li B2
is fitted
.
with the coding pin
.
to the required position
to clamp the blade
. Ensure
sits firmly on the neck
. Failure
can be screwed onto
Use only grinding discs whose permissible
speed rating is at least as high as that on the
type plate on the power tool.
RISK OF INJURY! Press the spindle locking
button
only when the mounting spindle
is at a complete standstill.
Press the spindle locking button
motor.
Undo the clamping nut
mounting spanner
Place the rough grinding or cutting disc with
the label side towards the appliance on the
mounting flange
Then replace the clamping nut
side facing up on the mounting spindle
With thin grinding discs (see fig. 1):
The collar of the clamping nut
so that a thin grinding disc can be fitted safely.
Fig. 1
Press the spindle locking button
motor.
Tighten the clamping nut
mounting spanner
With thick grinding discs (see fig. 2):
Fig. 2
The collar of the clamping nut
so that the grinding disk can be fitted securely onto
the mounting spindle
to lock the
using the two-hole
(see fig D).
.
with the raised
.
faces upwards
≤ 3,2 mm
to lock the
using the two-hole
.
> 3,2 mm
faces downwards
.
GB │ IE │ NI
 13
12