2. Drill 4 pilot holes on the back panel of recess box
using #21 drill bit to install the mounting bracket.
Install mounting bracket using 4 no.10 screws
(Figure 8).
Figure 8
3. Remove and discard current locking bracket
(Figure 9).
Figure 9
4. Install new locking bracket-retro fit (longer than
current bracket) using 8-32 nuts and washers
(Figure 10).
Figure 10
8-32 Nuts and
Washers
4 X No. 10
Screws
Mounting
Bracket
Current Locking Bracket
Locking Bracket-Retro Fit
1. Remove two screws holding the exhaust adapter
ring (Figure 11).
Figure 11
2 X No.8 Screws
2. Remove and discard the exhaust adapter ring
(Figure 12).
Figure 12
Exhaust
Adapter Ring
3. Install the vent cap on the water heater (Figure 13).
Figure 13
Vent Cap
4. Ensure that the vent cap is facing towards the
front of water heater and properly seated.
Secure vent cap using 2 screws (Figure 14).
Figure 14
2 x No.8
Screws