Philips 48OLED806/12 Service Manual page 29

Table of Contents

Advertisement

Remark: Under main menu "NVM editor", you can use the UP/DOWN keys to view and change the set Type number, the set Production Number or
the 18AC of a part.(The NVM-editor still has the same function as before, alpha-numeric entry.)
4.3 Factory mode:
Purpose
To perform extended alignments.
Specifications
Displaying and or changing Panel ID information.
Displaying and or changing Tuner ID information.
Error buffer clearing.
Various software alignment settings.
Testpattern displaying.
Public Broadcasting Service password Reset.
etc.
How to Activate the Factory mode
To activate the Factory mode, use the following method:
Press the following key sequence on the remote control transmitter: from the "menu/home" press "1999", directly followed by the
"Back/Return" button. Do not allow the display to time out between entries while keying the sequence.
After entering the Factory mode, we can see many items displayed, use the UP/DOWN keys to display the next/previous menu items
Factory mode overview
How to Exit the Factory mode
Select EXIT_FACTORY from the menu and press the "OK" button.