Sony XR-65X95K Service Manual page 13

Hide thumbs Also See for XR-65X95K:
Table of Contents

Advertisement

SELF DIAGNOSIS FUNCTION
Retry Limitation By Remote / Power Key
Smart Core
Red LED blinking count
2x
MAIN_POWER
DC_ALERT (5V)
3x
AUD_ERR
LD_ERR
4x
BCM_ERR
5x
P_ID_ERR
6x
BACKLIGHT
7x
TEMP_ERR
8x
4KBE_ERR
*1) If STDWN_OFFON_CNT <= STDWN_RTRY_LIMIT, and STDWN_OFFON_CNT_MAIN_POWER <= STDWN_RTRY_LIMIT_MAINPOWR, you can turn the set on by a
remote/power key. At this time, if the error occurs again, the STDWN_OFFON_CNT is incremented by 1.
*2) When the main micro operates normally for STDWN_OFFON_CLR = 60 minutes, STDWN_OFFON_CNT and STDWN_OFFON_CNT_MAIN_POWER are cleared.
Error Name
Retry Permission Times
STDWN_RTRY_LIMIT_MAINPOWR = 1
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
STDWN_RTRY_LIMIT = 2
*1
Note
Number of off/on action for
MAIN_POWER shutdown is recorded to
STDWN_OFFON_CNT_MAIN_POWER
Number of off/on action during the
error shutdown is recorded to
STDWN_OFFON_CNT
*2
*2
13