Only use the appliance in private households. The appliance is intended for cleaning with steam and can be used with appropriate accessories as described in these operating instructions. Detergents are not required. Observe the safety instructions.
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.
Missing or modified safety devices
Safety devices are provided for your own protection.
Never modify or bypass safety devices.
(according to type of appliance)
Risk of burns, surface of appliance becomes hot during operation | |
Risk of scalding from steam |
The pressure controller keeps the pressure in the steam boiler as constant as possible during operation. The heating is switched off when the maximum operating pressure is reached in the steam boiler and is activated if there is a pressure drop in the steam boiler as a result of a steam removal.
The safety lock seals the steam boiler from the steam pressure present. If the pressure regulator is defective and overpressure occurs in the steam boiler, an pressure relief valve opens in the safety lock and steam leaks out through the lock.
Prior to restarting the appliance, contact the responsible KÄRCHER Customer Service.
The safety thermostat prevents the device from overheating. If the pressure controller fails and the device overheats, then the safety thermostat switches the device off.
To reset the safety thermostat, contact the responsible KÄRCHER Customer Service.
The maximum amount of equipment is described in these operating instructions. Depending on the model used, there are differences in the scope of delivery (see packaging).
Illustration A
** optional
Note
Warm water reduces the heating-up time.
Note
Descaling the steam boiler is not required if commercially available distilled water is used.
Note
The device heating always switches on again during use to maintain the pressure in the steam boiler. The orange indicator light - heating illuminates to indicate this.
The expelled steam volume is regulated using the selector switch for steam volume. The selector switch has 3 positions:
Maximum steam volume | |
Reduced steam volume | |
No steam - child lock Note |
If the steam volume is reduced during work or if no more steam volume comes out, the water will have to be refilled.
Rinse the appliance's steam boiler after max. every tenth boiler fill.
ATTENTION
Material damage due to a stuck safety lock
If the safety lock is not removed after cleaning, there is a possibility that the lock could get stuck in the thread.
After cleaning, unscrew the safety lock and store it, for example, with the other device accessories.
We recommend sweeping the floor or vacuum cleaning it before using the appliance. In this way the floor will be cleared of dirt and loose particles before the wet cleaning.
Prior to using the appliance, always check the compatibility of the textiles at a concealed point: Steam down the textile, allow it to dry and then check it for any change in colour or shape.
ATTENTION
Damaged surfaces
Steam can loosen wax, furniture polish, plastic coatings or paint and edge band from edges.
Do not direct the steam at glued laminated edges as the edge band may loosen.
Do not use the appliance for cleaning unsealed wood or parquet floors.
Do not use the appliance for cleaning painted or plastic coated surfaces such as kitchen or living room furniture, doors or parquet.
ATTENTION
Glass breakages and damaged surfaces
Steam can damage sealed points of the window frame and, at low outside temperatures, lead to tension on the surface of window panes and hence to glass breakages.
Do not direct the steam at sealed points on the window frame.
At low outside temperatures, heat up the window panes by gently steaming the full surface of the glass.
The steam gun can be used for the following applications without accessories:
The small round brush is used for cleaning stubborn dirt. Stubborn dirt can be removed more easily by brushing.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces.
It is not suitable for cleaning sensitive surfaces.
The large round brush is suitable for cleaning large rounded surfaces, e.g. wash basin, shower tray, bath tub, kitchen sink.
ATTENTION
Damaged surfaces
The brush may scratch sensitive surfaces.
It is not suitable for cleaning sensitive surfaces.
The power nozzle is used for cleaning stubborn dirt, blowing down corners, joins etc.
The manual nozzle is used for cleaning small areas that can be washed down, shower cubicles and mirrors.
The floor nozzle is used for cleaning washable wall and floor coverings e.g. stone floors, tiles and PVC floors.
ATTENTION
Damage due to build-up of steam
Heat and moisture can lead to damage.
Check the heat resistance and steam effect on an inconspicuous area using a minimal volume of steam prior to use.
Note
Detergent residue or care emulsions on the surface to be cleaned can lead to streaks during steam cleaning, which will disappear however once these have been used several times.
We recommend sweeping the floor or vacuum cleaning it before using the device. In this way the floor will be cleared of dirt and loose particles before the wet cleaning commences. Work slowly on surfaces that are heavily soiled so that the steam has longer to take effect.
The floor cleaning cloth will stick to the floor nozzle of its own accord due to the hook and loop fastener.
Note
Initially, the floor cleaning cloth's hook and loop fastener strip is very strong and cannot be removed from the floor nozzle easily. After the floor cleaning cloth has been used several times and washed, it is easier to remove from the floor nozzle and it has reached the optimum adhesion.
Note
Since the lime becomes caked on the appliance, we recommend descaling the appliance as specified in the table (BF=boiler fillings) based on the number of times the steam boiler is filled.
Hardness range | °dH | mmol/l | KF | |
I | soft | 0-7 | 0-1.3 | 55 |
II | Medium | 7-14 | 1.3-2.5 | 45 |
III | Hard | 14-21 | 2.5-3.8 | 35 |
IV | Very hard | >21 | >3.8 | 25 |
Note
Your water board or municipal utilities authority can provide information on hardness of tap water.
ATTENTION
Damaged surfaces
The descaler may corrode sensitive surfaces.
Fill and empty the appliance carefully.
ATTENTION
Appliance damage due to descaler
An unsuitable descaler and incorrect dosing of the descaler may damage the appliance.
Only use KÄRCHER descaler.
Use 2 dosing units of the descaler for 1.0 l of water.
(Accessories - depending on scope of delivery)
Note
The micro fibre cloths are not suitable for dryer.
Note
When washing the cloths, observe the instructions on the washing tag. Do not use any liquid softeners as this will affect the ability of the cloths to pick up dirt.
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
Risk of electric shock and burns
Trying to eliminate faults while the appliance is connected to the mains or has not yet cooled down is always dangerous.
Remove the mains plug.
Allow the appliance to cool down.
The steam boiler is scaled.
No water in the steam boiler
The steam lever is locked with the child lock.
The steam lever is released.
The steam boiler is scaled.
The steam boiler is too full.
The steam boiler is scaled.
Electrical connection | ||
Voltage | V | 220-240 |
Phase | ~ | 1 |
Frequency | Hz | 50-60 |
Protection class | IPX4 | |
Protection category | I | |
Performance data | ||
Heating capacity | W | 1500 |
Maximum operating pressure | MPa | 0.32 |
Heating-up time | Minutes | 6.5 |
Continuous steaming | g/min | 40 |
Maximum steam blast | g/min | 100 |
Filling quantity | ||
Steam boiler | l | 1.0 |
Dimensions and weights | ||
Weight (without accessories) | kg | 3.1 |
Length | mm | 380 |
Width | mm | 254 |
Height | mm | 260 |
Subject to technical modifications.