8. Service Mode Function
MPU controls the functions switching for each IICs through IIC bus in this chassis. The following setting and adjustment can be
adjusted by remote control in Service Mode.
8.1. How to enter SERVICE
Simultaneously press MUTE button (
RED GAIN 32
Key Command
* Press the selection button (
* Press the selection button (
* Each adjustment values will stored automatically.
8.2. How to exit SERVICE
To exit from Service mode, press menu or Power button on remote control.
) on remote control and program DOWN button (
GRN GAIN 32
OPTION1
3C
OPTION 2
4F
ADC CLAMP
RED 17
ADC CLAMP
GREEN 18
) or program up/down button (
) or volume up/down button(
13
) on the TV set.
BLUE GAIN 32
AGC LEVEL 00
AVL 00
ADC GAIN
BLUE 22
ADC CLAMP
BLUE 02
) to step up/down through the functions.
) to change the function values.
TX-20LB5F/G
TX-20LB5P/G
RED BIAS 00
GRN BIAS 00
ADC GAIN
RED 22
ADC GAIN
GREEN 22
CCU OFF
SHIPPING
4F 3C