OPERATING INSTRUCTIONS

LEAK CHECK

WARNING!
Perform all leak tests outdoors.
NEVER leak test when smoking.
Do not use the appliance until all connections have been leak tested and do not leak
Hose / Regulator
Connection
1. Make 2-3 oz. of leak test solution (one part liquid dishwashing detergent and three parts water).
2. Apply several drops of solution where hose attaches to regulator.
3. Apply several drops of solution where regulator connects to cylinder.
4. Make sure all valves are turned OFF.
5. Turn cylinder valve ON.
If bubbles appear at any connection there is a leak.
1. Turn cylinder valve OFF.
2. If leak is at hose/regulator connection: tighten connection and perform another leak test. If bubbles continue appearing, the
hose should be returned to the place of purchase.
3. If leak is at regulatory/cylinder valve connection: disconnect, reconnect, and perform another leak test. If you continue to
see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder's place of purchase.
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test. Complete installation.