Gigabyte R283-S96-AAE1 User Manual

Rack server - 4th/5th gen intel xeon scalable
Table of Contents

Advertisement

Quick Links

R283-S96-AAE1
R283-S96-AAJ1
Rack Server - 4th/5th Gen Intel® Xeon® Scalable
2U DP 12+2-Bay Gen5 NVMe/SATA/SAS4
1+1 2000W (240V) 80 PLUS Platinum redundant power supplies (AAE1)
1+1 2000W (240V) 80 PLUS Titanium redundant power supplies (AAJ1)
User Manual
Rev. 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Gigabyte R283-S96-AAE1

  • Page 1 R283-S96-AAE1 R283-S96-AAJ1 Rack Server - 4th/5th Gen Intel® Xeon® Scalable 2U DP 12+2-Bay Gen5 NVMe/SATA/SAS4 1+1 2000W (240V) 80 PLUS Platinum redundant power supplies (AAE1) 1+1 2000W (240V) 80 PLUS Titanium redundant power supplies (AAJ1) User Manual Rev. 1.0...
  • Page 2 For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com...
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ................... 11 Installation Precautions .................. 11 Product Specifications ..................12 System Block Diagram ................... 16 Chapter 2 System Appearance ..................17 Front View ...................... 17 Rear View ....................... 18 Front Panel LEDs and Buttons ............... 19 RoT LEDs .......................
  • Page 8 4-4-1 CBP20C7 ........................51 4-4-2 CBP2025 (Rear System Storage Board) ..............52 Chapter 5 BIOS Setup ....................53 The Main Menu ....................55 Advanced Menu ..................... 58 5-2-1 Trusted Computing ....................59 5-2-2 Serial Port Console Redirection ................60 5-2-3 SIO Configuration ....................63 5-2-4 PCI Subsystem Settings ..................64 5-2-5 USB Configuration ....................66 5-2-6...
  • Page 9 BIOS Recovery .................... 114 BIOS POST Beep code (AMI standard) ............115 5-9-1 PEI Beep Codes ....................115 5-9-2 DXE Beep Codes ....................115 - 9 -...
  • Page 10 This page intentionally left blank - 10 -...
  • Page 11: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 12: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System Security Server Socket Operating Properties Š 2U Dimension Š 438 (W) x 87.5 (H) x 815(D) mm System fan Power Supply Superchip Š...
  • Page 13 Storage Front side: Š 12 x 3.5"/2.5" Gen5 NVMe/SATA/SAS4 hot-swappable bays Š (6 x NVMe from CPU_0, 6 x NVMe from CPU_ Rear side: Š 2 x 2.5" SATA/SAS4 hot-swappable bays SAS card is required for SAS devices support Š Depends on SAS add-on card RAID Š...
  • Page 14 Operating Properties Š Optional TPM2.0 kit: CTM010 Superchip System fan Power Supply Power Supply R283-S96-AAE1 Š 1+1 2000W (240V) 80 PLUS Platinum redundant power supplies AC Input: Š 100-120V~/ 12A, 50-60Hz Š 180-240V~/ 10A, 50-60Hz DC Input: Š 240Vdc/ 10A DC Output: Š...
  • Page 15 Š + 12.2V/ 164A Š + 12.2Vsb/ 3A System Š Aspeed® AST2600 management controller Management Š GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š...
  • Page 16: System Block Diagram

    System Block Diagram cket Security Server Operating Properties Operating Operating temperature: 10°C to 35°C Š Operating humidity: 8%-80% (non-condensing) Properties Š Superchip System fan Power Supply Non-operating temperature: -40°C to 60°C Š Non-operating humidity: 20%-95% (non-condensing) Š NVMe x6 SATA x14 NVMe x6 12-bay 3.5"/2.5"...
  • Page 17: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View HDD0 HDD3 HDD6 HDD9 HDD1 HDD4 HDD7 HDD10 HDD2 HDD5 HDD8 HDD11 Description Front Panel LEDs and Buttons USB 3.2 Gen1 Port x 2 Note! Drives with green latches support NVMe. • Refer to section 2-3 Front Panel LEDs and Buttons for a detailed description of the function of the LEDs.
  • Page 18: Rear View

    Rear View SLOT12 SLOT11 SLOT8 SLOT6 SLOT4 SLOT3 PSU2 PSU1 SLOT2 SLOT1 Description Description Mini DP Port Server Management LAN Port ID LED OCP 3.0 Slot (Option/SFF) USB 3.2 Gen1 Port x 2 PCIe Slot 1GbE LAN Port x 2 2.5”...
  • Page 19: Front Panel Leds And Buttons

    Front Panel LEDs and Buttons No. Name Color Status Description Reset Button Press this button to reset the system. Press this button for the server to generate a NMI to the NMI button processor. If multiple-bit ECC errors occur, the server will effectively be halted.
  • Page 20: Rot Leds

    RoT LEDs ID LED Status LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images Blinks Blue Blinks Green Recovering BMC Active Flash 4 times per second 4 times per second...
  • Page 21 Active Flash Authentication (AUTH) Fail Blinks Blue Blinks Green BMC : AUTH Fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Amber BIOS : AUTH fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Green 2 times per second 2 times per second...
  • Page 22: Rear System Lan Leds

    Rear System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green 1GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 23: Power Supply Unit Led

    Power Supply Unit LED NOTE! The power supply may be vary based on the system configuration. PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updating mode AC cord unplugged or AC power lost;...
  • Page 24: Hard Disk Drive Leds

    Hard Disk Drive LEDs LED #1 2.5” HDD LED #2 3.5” HDD LED #1 LED #2 HDD Present RAID SKU LED #1 Locate Rebuilding HDD Access Fault (No Access) Green ON(*1) BLINK (*2) Disk LED (LED on Back Panel) Amber No RAID configuration Removed HDD...
  • Page 25: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 26: Removing And Installing The Chassis Cover

    Removing and Installing the Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the chassis cover: Remove the screw securing the chassis cover. Unlock the plastic handle and pull the grip handle to open the panel cover.
  • Page 27: Removing And Installing The Hard Disk Drive

    Removing and Installing the Hard Disk Drive Read the following guidelines before you begin to install the hard disk drive: • Take note of the HDD tray orientation before sliding it out. • The tray will not fit back into the bay if it is inserted incorrectly. •...
  • Page 28 Follow these instructions to install a 2.5" hard disk drive into 3.5" HDD Tray: Press the release button. Extend the locking lever. Pull the locking lever in the direction indicated to remove the HDD tray. Align the hard disk drive with the positioning screw on the HDD tray. Secure the hard disk drive with five screws.
  • Page 29: Removing And Installing The Fan Duct

    Removing and Installing the Fan Duct Follow these instructions to remove the fan duct: Lift up to remove the fan duct. To reinstall the fan duct, align the fan duct with the guiding groove. Push down the fan duct until it is firmly seated on the system.
  • Page 30: Removing And Installing The Heat Sink

    Removing and Installing the Heat Sink Read the following guidelines before you begin to install the heat sink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage. •...
  • Page 31: Installing The Cpu And Heat Sink

    Installing the CPU and Heat Sink Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 32 Carrier Types used for Package Types Package Type Xeon® SP XCC Xeon® SP MCC Xeon® SP+HBM Carrier Code NOTE! • The carrier code is marked on each carrier and matches a code laser marked on to the IHS(Integrated Heat Spreader) to ensure the right parts are used together. •...
  • Page 33: Removing And Installing Memory

    Removing and Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 34: Removing And Installing A Memory Module

    3-6-2 Removing and Installing a Memory Module Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on to this motherboard.
  • Page 35: Dimm Population Table

    3-6-3 DIMM Population Table 4th Gen Intel Xeon Scalable Processors-SP Memory Support Speed (MT/s); Voltage (V); DIMM per Channel (DPC) Ranks Per DIMM and DIMM Capacity (GB) Type Data Width 1DPC 2DPC 16Gb 24Gb 36Gb 1.1V SRx8 (RC D) 16GB 24GB SRx4 (RC C) 32GB...
  • Page 36: Processor And Memory Module Matrix Table

    3-6-4 Processor and Memory Module Matrix Table Memory Q’ty CPU0 CPU1 for each CPU 1 DIMM 2 DIMM 4 DIMM 6 DIMM 8 DIMM 12 DIMM 16 DIMM System Hardware Installation - 36 -...
  • Page 37: Removing And Installing The Pcie Card

    Removing and Installing the PCIe Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 38 System Hardware Installation - 38 -...
  • Page 39: Installing The Mezzanine Card

    Installing the Mezzanine Card 3-8-1 Installing the OCP 3.0 Mezzanine Card Use of the following type of OCP 3.0 NIC is recommended: • OCP 3.0 SFF with pull tab • OCP 3.0 SFF with ejector latch Follow these instructions to install an OCP 3.0 Mezzanine card: Remove the two screws securing the OCP 3.0 card slot cover.
  • Page 40: Replacing The Fan Assembly

    Replacing the Fan Assembly • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered-down and all power sources have been disconnected from the server prior to replacing a system fan.
  • Page 41: Removing And Installing The Power Supply

    3-10 Removing and Installing the Power Supply Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle. Press the retaining clip on the right side of the power supply unit in the direction indicated. Pull out the power supply unit using the handle.
  • Page 42: Cable Routing

    3-11 Cable Routing CPU0 CPU1 Motherboard: FP_1 Front IO Board: FP_1 Front Panel LEDs and Buttons Cable Front IO Board: FP_1 Motherboard: FUSB_1 Front Panel USB 3 Ports Cable System Hardware Installation - 42 -...
  • Page 43 CPU0 CPU1 Motherboard: BP_1 HDD Backplane Board Signal Cable Front HDD Board: BP_1 Front HDD Board: BP_SERIES HDD Backplane Board Signal Cable Rear HDD Board: BP_1 System Hardware Installation - 43 -...
  • Page 44 CPU0 CPU1 Motherboard: BP_ATX1 HDD Backplane Board Power Cable Front HDD Board: ATX1 Motherboard: ATX2 HDD Backplane Board Power Cable Rear HDD Board: BP_2X3 System Hardware Installation - 44 -...
  • Page 45 CPU0 CPU1 Motherboard: Motherboard: SATA0 SATA2 SATA Cable SATA Cable Front HDD Board: Front HDD Board: SL_SAS0 SL_SAS2 Motherboard: Motherboard: SATA1 SATA3 SATA Cable SATA Cable Front HDD Board: Rear HDD Board: SL_SAS1 SL_SAS0 System Hardware Installation - 45 -...
  • Page 46 CPU0 CPU1 Motherboard: Motherboard: U2_P0_3EG U2_P1_3EG NVMe 0-1 NVMe 6-7 Front HDD Board: Front HDD Board: Cable Cable A1: U.2_0 D1: U.2_6 A2: U.2_1 D2: U.2_7 Motherboard: Motherboard: U2_P0_4CA U2_P1_4CA NVMe 2-3 NVMe 8-9 Front HDD Board: Front HDD Board: Cable Cable B1: U.2_2...
  • Page 47: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components CPU0 CPU1 Item Description 2 x 3 Pin ATX Power Connector 2 x 3 Pin ATX Power Connector 2 x 7 Pin Power Connector MCIO Connector (U2_P1_4GE/4CA) 2 x 2 Pin P12V Backplane Power Connector MCIO Connector (U2_P1_3AC/3EG) MCIO Connector (U2_P0_4GE/4CA) 2 x 2 Pin P12V Backplane Power Connector...
  • Page 48 Item Description SlimLine Connector (Left to Right SATA0/SATA1/SATA2/SATA3) System Battery TPM Module Connector (SPI Interface) G-SC Module Connector OCP 3.0 Connector (PCIe Gen5 x16) Riser Connector #3 (PCIe x16) Riser Connector #4 (PCIe x16) Power Supply Connector#2 (Secondary) P12V GPU Power Connector (P12V_S11) Motherboard Components - 48 -...
  • Page 49: Jumper Settings

    Jumper Settings Clear CMOS CLR_CMOS Default Enable BMC Readiness LED BMC1 BMC2 BIOS2 BIOS1 CPU0 CPU1 NCSI Sw ch G-SC MB SW.1 J4.3 Onboard LAN ON OFF Slot#1 OCP3.0 Slot#2 OCP3.0 HSMB_SEL BIOS defined PMBUS_SEL BIOS defined Stop initial power on S3_MASK Normal [Default] when BMC is not ready...
  • Page 50: G-Sc Module

    G-SC Module 4-3-1 CDCR112 BMC1 BMC2 BIOS2 BIOS1 Item Description 10/100/1000 Server Management LAN Port 1GbE LAN Port #2 1GbE LAN Port #1 USB 3.2 Gen1 Port x 2 Mini DP Port Motherboard Components - 50 -...
  • Page 51: Backplane Board Storage Connector

    Backplane Board Storage Connector 4-4-1 CBP20C7 Item Description MCIO 4i (SFF-TA1016/U.2_0) MCIO 4i (SFF-TA1016/U.2_1) MCIO 4i (SFF-TA1016/U.2_2) MCIO 4i (SFF-TA1016/U.2_3) MCIO 4i (SFF-TA1016/U.2_4) MCIO 4i (SFF-TA1016/U.2_5) MCIO 4i (SFF-TA1016/U.2_6) MCIO 4i (SFF-TA1016/U.2_7) MCIO 4i (SFF-TA1016/U.2_8) MCIO 4i (SFF-TA1016/U.2_9) MCIO 4i (SFF-TA1016/U.2_10) MCIO 4i (SFF-TA1016/U.2_11) SlimSAS 4i Connector (SFF-8654/SAS_SAS0)
  • Page 52: Cbp2025 (Rear System Storage Board)

    4-4-2 CBP2025 (Rear System Storage Board) Item Description MCIO 4i (SFF-TA1016/U_2_0) MCIO 4i (SFF-TA1016/U_2_1) limSAS Connector (SFF-8654/SL_SAS0 Motherboard Components - 52 -...
  • Page 53: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 54  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 55: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 56 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version Displays BMC firmware version information.
  • Page 57 Parameter Description Memory Frequency Displays the frequency information of the installed memory. Onboard LAN Information (Note3) LAN# MAC Address Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. (Note3) The number of LAN ports listed will depend on the motherboard / system model.
  • Page 58: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 58 -...
  • Page 59: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be TPM v1.2 Support available. Options available: Disable, Enable. Default setting is Enable. BIOS Setup - 59 -...
  • Page 60: Serial Port Console Redirection

    5-2-2 Serial Port Console Redirection Parameter Description Console redirection enables the users to manage the system from a COM1 Console remote location. Redirection (Note) Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items. Please note that this item is configurable when COM1 Console Redirection is set to Enabled.
  • Page 61 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 62 Parameter Description Serial Port for Out-of-Band Management / Windows EMS console redirection allows the user to configure Console Redirection Emergency Management Settings to support Out-of-Band Serial Port management. Services (EMS) Console Options available: Enabled, Disabled. Default setting is Disabled. Redirection (Note) Press [Enter] to configure advanced items.
  • Page 63: Sio Configuration

    5-2-3 SIO Configuration Description Parameter Displays the AMI SIO driver version information. AMI SIO Driver Version Super IO Chip Logical Device(s) Configuration Press [Enter] to configure advanced items. Use This Device Š – When set to Enabled allows you to configure the serial port settings. When set to Disabled, displays no configuration for the serial port.
  • Page 64: Pci Subsystem Settings

    5-2-4 PCI Subsystem Settings BIOS Setup - 64 -...
  • Page 65 Parameter Description PCI Bus Driver Version Displays the PCI Bus Driver version information. When enabled, this setting will initialize the device expansion SLOT_# I/O ROM ROM for the related PCI-E slot. (Note1) Options available: Enabled, Disabled. Default setting is Enabled. SLOT_# Lanes Change the PCIe lanes.
  • Page 66: Usb Configuration

    5-2-5 USB Configuration Parameter Description USB Configuration USB Devices: Displays the USB devices connected to the system. Enable/Disable the XHCI (USB 3.0) Hand-off support. XHCI Hand-off Options available: Enabled, Disabled. Default setting is Enabled. USB Mass Storage Driver Enable/Disable the USB Mass Storage Driver Support. Support Options available: Enabled, Disabled.
  • Page 67: Network Stack Configuration

    5-2-6 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support Options available: Enabled, Disabled.
  • Page 68: Post Report Configuration

    5-2-7 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 68 -...
  • Page 69: Nvme Configuration

    5-2-8 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. Options available: BIOS Build-In, NVMe Device. Default setting is BIOS NVMe OPROM Select Build-In. BIOS Setup - 69 -...
  • Page 70: Chipset Configuration

    5-2-9 Chipset Configuration Parameter Description Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Restore on AC Power Loss (Note) Power Off, the system remains off after power shutdown.
  • Page 71: Tls Auth Configuration

    5-2-10 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 72: Iscsi Configuration

    5-2-11 iSCSI Configuration Parameter Description Press [Enter] configure advanced items. Attempt Priority Š Attempt Priority – Use arrow keys to select the attempt, then press +/- keys to move the attempt up/down in the attempt order list. Commit Changes and Exit Š...
  • Page 73: Intel(R) I350 Gigabit Network Connection

    5-2-12 Intel(R) i350 Gigabit Network Connection BIOS Setup - 73 -...
  • Page 74 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 75: Vlan Configuration

    5-2-13 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 76: Driver Health

    5-2-14 Driver Health Parameter Description Driver Health Displays driver health status of the devices/controllers if installed BIOS Setup - 76 -...
  • Page 77: Chipset Menu

    Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub(PCH). Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 77 -...
  • Page 78 5-3-1 Processor Configuration BIOS Setup - 78 -...
  • Page 79: Processor Configuration

    Description Parameter Processor Configuration Press [Enter] to configure advanced items. CPU Socket 0 Configuration Š – Core Disable Bitmap(Hex) • Number of Cores to enable. 0 means all cores. FFFFFFF Pre-Socket Configuration means to disable all cores. The maximum value depends on the number of CPUs available.
  • Page 80 Description Parameter Enable/Disable memory encryption (TME). Memory Encryption (TME) (Note) Options available: Enabled, Disabled. Default setting is Disabled. Total Memory Encryption Options available: Enabled, Disabled. Default setting is Disabled. Multi-Tenant (TME-MT) Press [Enter] to configure advanced items. Provision S3M CFR Š...
  • Page 81: Common Refcode Configuration

    5-3-2 Common RefCode Configuration Parameter Description Common RefCode Configuration Divide physical NUMA nodes into evenly sized virtual NUMA nodes in ACPI table. This may improve Windows performance on CPUs Virtual Numa with more than 64 logical processors. Options available: Enable, Disable. Default setting is Disable. BIOS Setup - 81 -...
  • Page 82: Upi Configuration

    5-3-3 UPI Configuration Description Parameter Press [Enter] to configure advanced items. UPI Status Š – Press [Enter] to view the Uncore status. Link Frequency Select Š – Selects the UPI link frequency. – Options available: 12.8GT/s, 14.4GT/s, 16.0GT/s, Auto, Use Per Link Setting.
  • Page 83 Description Parameter MMIO High Granularity Size Š – Selects the allocation size used to assign mmioh resources. – Options available: 1G, 4G, 16G, 64G, 256G, 1024G. Default setting is UPI General Configuration 64G. (continued) Clock Modulation Enabled Š – Options available: Disable, Enable, Auto. Default setting is Auto. BIOS Setup - 83 -...
  • Page 84: Memory Configuration

    5-3-4 Memory Configuration Description Parameter Integrated Memory Controller (iMC) When set to Enable, the system enforces Plan Of Record restrictions for DDR frequency programming. Enforce DDR Memory Frequency POR Options available: POR, Disable. Default setting is POR. Configures the maximum memory frequency. If Enforce POR is disabled, user will be able to run at higher frequencies than the Memory Frequency memory support (limited by processor support).
  • Page 85 Description Parameter Enable/Disable Assert ADR on S5. Assert ADR on S5 Options available: Enabled, Disabled. Default setting is Disabled. Auto is the detected SPD value and use it, otherwise use BIOS Build-in. Get Memory Timing Options available: Auto, BIOS Build-in. Default setting is BIOS Build-in. Press [Enter] to view memory topology with DIMM population Memory Topology information.
  • Page 86 Description Parameter Leaky bucket time window based interface Hour Š – Leaky bucket time window based interface hour used for DDR (0-24). – Press the <+> / <-> keys to increase or decrease the desired values. Leaky bucket time window based interface Minute Š...
  • Page 87: Iio Configuration

    5-3-5 IIO Configuration Description Parameter IIO Configuration Press [Enter] to configure advanced items. ® Intel VT for Directed I/O Š – Enable/Disable the Intel VT for Directed I/O (VT-d) support function by reporting the I/O device assignment to VMM through DMAR ACPI Tables.
  • Page 88 Description Parameter Interrupt Remapping Š – Enable/Disable the interrupt remapping support function. – Options available: Auto, Enable, Disable. Default setting is Auto x2APIC Opt Out Š – Options available: Enable, Disable. Default setting is Disable. Pre-boot DMA Protection Š – Options available: Enable, Disable. Default setting is Disable. Press [Enter] to configure advanced items.
  • Page 89: Advanced Power Management Configuration

    5-3-6 Advanced Power Management Configuration Description Parameter Press [Enter] to configure advanced items. SpeedStep (Pstates) Š – Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load. – Options available: Enable, Disable. Default setting is Enable. CPU P State Control Turbo Mode Š...
  • Page 90 Description Parameter Press [Enter] to configure advanced items. Enable Monitor MWAIT Š – Allows Monitor and MWAIT instructions. – Options available: Disable, Enable, Auto. Default setting is Auto. CPU C6 Report Š CPU C State Control – Enable/Disable CPU C6(ACPI C3) report to OS. –...
  • Page 91: Pch Configuration

    5-3-7 PCH Configuration Description Parameter PCH-IO Configuration Press [Enter] to configure advanced items. SATA Configuration Š – Enable/Disable SATA controller. – Options available: Enabled, Disabled. Default setting is Enabled. SATA Mode Selection Š – Configures on chip SATA type. – AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality.
  • Page 92 Description Parameter Port 0/1/2/3/4/5/6/7 Š – Enable/Disable Port 0/1/2/3/4/5/6/7 device. – Options available: Enabled, Disabled. Default setting is Enabled. Hot Plug (for Port 0/1/2/3/4/5/6/7) SATA And RST Š – Enable/Disable HDD Hot-Plug function. Configuration/ – Options available: Enabled, Disabled. Default setting is Enabled. SATA Controller And RST Spin Up Device (for Port 0/1/2/3/4/5/6/7) Configuration (continued)
  • Page 93: Miscellaneous Configuration

    5-3-8 Miscellaneous Configuration Description Parameter Miscellaneous Configuration Selects the active video type. Options available: Auto, Onboard Device, PCIE Device, Specific PCIE Active Video Device. Default setting is Auto. Enables Spread spectrum - only affects external clock generator. Options available: SSC Off, SSC = -0.3%, SSC = -0.5%, Hardware. External SSC - CK440 Default setting is SSC Off.
  • Page 94: Server Me Configuration

    5-3-9 Server ME Configuration Parameter Description General ME Configuration Oper. Firmware Version Displays the operational firmware version. ME Firmware Status #1/#2 Displays ME Firmware status information. Current State Displays ME Firmware current status information. Error Code Displays ME Firmware status error code. Recovery Cause Displays ME Firmware recovery cause.
  • Page 95: Runtime Error Logging Settings

    5-3-10 Runtime Error Logging Settings Description Parameter Runtime Error Logging Enable/Disable system error logging function. System Errors Options available: Enable, Disable. Default setting is Enable. Enable/Disable software injection error logging function. S/W Error Injection Support Options available: Enable, Disable. Default setting is Disable. Press [Enter] to configure advanced items.
  • Page 96 Description Parameter Press [Enter] to configure advanced items. PCIE Error Š – Enable/Disable PCIE error. – Options available: Enable, Disable. Default setting is Disable. Uncorrected Error (Note) Š – Enables and escalates Uncorrectable/Recoverable Errors to error pins. – Options available: Enable, Disable. Default setting is Enable. Fatal Error Enable (Note) Š...
  • Page 97: Power Policy

    5-3-11 Power Policy Description Parameter Selects a Power Policy Quick Setting. Options available: Standard, Best Performance, Energy Efficient. Default Power Policy Quick Settings setting is Standard. Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor SpeedStep (Pstates) load.
  • Page 98 Description Parameter Enables Logical processor (Software Method to Enable/Disable Logical Processor threads). Enable LP [Global] Options available: ALL LPs, Single LP. Default setting is ALL LPs. Options available: Enable, Disable. Default setting is Enable. Hardware Prefetcher Options available: Enable, Disable. Default setting is Enable. Adjacent Cache Prefetch Options available: Enable, Disable.
  • Page 99: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled, Disabled. Default setting is Enabled. FRB-2 Timer Configures the FRB2 Timer timeout. The value is between 1 to 30 minutes. (Note1) timeout Default setting is 6 minutes. Configures the FRB2 Timer policy.
  • Page 100 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC VLAN Press [Enter] to configure advanced items. Configuration BMC network Press [Enter] to configure advanced items. Configuration IPv6 BMC Network Press [Enter] to configure advanced items.
  • Page 101: System Event Log

    5-4-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled, Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Options available: No, Erase SEL Yes, On next reset,...
  • Page 102: View Fru Information

    5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 102 -...
  • Page 103: Bmc Vlan Configuration

    5-4-3 BMC VLAN Configuration Description Parameter BMC VLAN Configuration Select to configure BMC VLAN ID. The valid range is from 0 to 4094. When BMC VLAN ID set to 0, BMC VLAN ID will be disabled. Select to configure BMC VLAN Priority. The valid range is from 0 to 7. BMC VLAN Priority When BMC VLAN ID is set to 0, BMC VLAN Priority will not be selected.
  • Page 104: Bmc Network Configuration

    5-4-4 BMC Network Configuration Parameter Description BMC network configuration Select NCSI and Dedicated Options available: Do Nothing, Model1(Dedicated), Model2(NCSI), Mode3(Failover). Default setting is Do Nothing. Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Configuration Address source Options available: Unspecified, Static, DynamicBmcDhcp.
  • Page 105: Ipv6 Bmc Network Configuration

    5-4-5 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 106: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 107: Secure Boot

    5-5-1 Secure Boot The Secure Boot feature is applicable if supported by your Operating System. If your Operating System is not supporting Secure Boot, the system will hang when starting the Operating System. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function.
  • Page 108 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 109 Parameter Description Authorized TimeStamps (DBT) Š – Displays the current status of the Authorized TimeStamps Database. – Press [Enter] to configure a new DBT or load additional DBT from storage devices. Key Management – Options available: Update, Append. (continued) OsRecovery Signatures Š...
  • Page 110: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 111 Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot order priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
  • Page 112: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save and Exit Options available: Yes, No.
  • Page 113 Parameter Description Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components Restore Defaults and you choose to load these settings, the system might not function properly.
  • Page 114 BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
  • Page 115 BIOS POST Beep code (AMI standard) 5-9-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...

This manual is also suitable for:

R283-s96-aaj1

Table of Contents