Sharp R-8580 Service Manual page 32

Convection microwave oven
Table of Contents

Advertisement

1.
2.
3.
4.
5.
5.
6.
8.
9.
MAGNETRON
REMOVAL
Disconnect
oven from
power
supply
and remove
outer case.
screws, a carefull
attention
should
be necessary to
Discharge
the high voltage capacitor.
prevent the magnetron
fall away.
Disconnect
wire leads from the magnetron.
6. Remove
the magnetron
(with
magnetron
cooling
Remove
the
magnetron
temp.
fuse
fitted
to
duct(B))
from the unit with
a careful
attention
the
waveguide
flange.
And release the wire leads from
magnetron
tube should
not hit by any metal object
around the tube.
the hole of magnetron
cooling
duct (B).
And re-
lease the AH sensor harness from hole of chassis
support.
Remove
four
(4)
screws
holding
the
chassis
support
to cooling
duct
(A),
waveguide,
rear cabinet,
control
back plate.
7. Remove one (1) screw holding
cooling
duct (B) to
the magnetron.
8. Remove cooling
duct (B) from the magnetron.
9. Now the magnetron
is free.
CAUTION:
Release the tab on cooling
duct (B) to hold cooling
duct (A).
Carefully
remove four (4) mounting
screws holding
the
magnetron
to waveguide,
when
remove
the
WHEN REPLACING
THE MAGNETRON,
BE SURE
THE
R.F.
GASKET
IS
IN
PLACE
AND
THE
MAGNETRON
MOUNTING
SCREWS ARE TIGHTENED
SECURELY.
CONVECTION
MOTOR
REMOVAL
Disconnect
oven from
power
supply
and remove
outer case.
Disharge the high voltage capacitor.
Remove
sliding
the thermal
cut-out
with
its wire
lead on.
Disconnect
wire
leads from the convection
motor
and convection
heater.
Disconnect
the 2-pin connector
from thermistor.
Remove eleven (11) screws holding
the heater duct
to the oven cavity.
Remove two (2) screws holding
the heater duct to
thermal protection
plate (bottom).
The heater unit is now free.
Remove
the four
(4) screws
holding
the thermal
protection
plate(left)
to the heater duct.
1 O.The thermal
protection
plate(left)
and sheet( left)
are now free.
11 .Remove
three
(3) screws
holding
the convection
motor mounting
plate to the heater duct.
12.Pull
the convection
motor shaft out of convection
fan.
13.Now
the convection
motor with
the motor mount-
ing plate is free.
1.
2.
3.
4.
5.
14.Remove
two (2) nuts holding
the motor mounting
plate to the convection
motor.
15.Convection
motor is now free.
Re-install
1. Re-install
the convection
motor
mounting
plate to
the convection
motor by the two (2) nuts.
2. Put the convection
fan to the motor shaft.(fit
with a
E-ring.)
3. Re-install
the heater duct to the convection
motor
mounting
plate by the three (3) screws.
4. Make sure the rotation
of the convection
motor.
5. Re-install
the thermal
protection
plate to cover the
heatewr
duct
with
sandwiching
the thermal
pro-
tection
sheet.
6. Re-install
the heater unit to the left side of the oven
cavity
by the eleven
(11)
screws.
Re-install
the
heater unit to thermal
protection
plate (buttom)
by
two (2) screws.
7. Re-install
the wire
leads to the convection
motor,
convection
heater, thermister
connector.
Refering to "Pictorial
diagram".
8. Re-install
the thermal cut-out.
COOLING
FAN MOTOR
REMOVAL
Disconnect
oven from
power
supply
and remove
outer case.
Discbarge
the high voltage
capacitor.
Disconnect
wire leads from the cooling
fan motor.
Release AH sensor
harness
from
chassis
support
and cooling
duct (A).
Remove four (4) screws
holding
the chassis sup-
port to rear cabinet,
cooling
duct
flange and control
panel back plate.
(A),
waveguide
6. Release the tab on cooling
duct (B) holding
cooling
duct (A).
-
7. Remove duct (A) with the cooling
fan motor from
the unit.
The cooling
fan motor assembly is now free.
8. Remove the fan blade from the cooling
fan motor
shaft by pulling
out the fan retainer clip.
9. Remove two
(2) screws and nuts holding
cooling
fan motor to the cooling
duct (A).
The cooling
fan motor is now free.
31