10. Remove functional part
10.1 Remove the sealing cap (see
10.2 Close the flow volume regulator.
☞
For technical reasons, always flows a little water.
10.3 Remove the safety ring.
10.4 Remove the pressure cap and spring.
10.5 Use a socket spanner to unscrew the functional part.
10.6 Reassemble in the reverse order.
11. Fault correction
Fault
Water does not flow at
all
Water flows continu-
ously
Water flow too weak
Water flow too large
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform the AQUA service department.
12. Replacement parts
Bezeichnung
1 Pressure cap . . . . . . . . . . . . . . . . . . .2000104784
1a Sealing cap with O-ring . . . . . . . . . . .2000109190
2 Functional part . . . . . . . . . . . . . . . . . .2000104372
3 Complete screw connections . . . . . . .2000105562
4 Rosette . . . . . . . . . . . . . . . . . . . . . . . .2000106020
Replacement kit comprising:
Rubber parts
Spring
Safety ring . . . . . . . . . . . . . . . . . .2000105617
Chapter
9.1).
Cause
– Water supply interrupted
– Flow volume regulator closed
– Functional part faulty
– Functional part faulty
– Flow volume regulator not fully
opened
– Supply pressure too low
– Flush volume adjustment incorrect
– Flush volume adjustment incorrect
Best.-Nr.
- 5 -
Remedy
➯ Restore
➯ Open it
➯ Replace it
➯ Replace it
➯ Open it
➯ Check it
➯ Adjust it
➯ Adjust it