Daikin Altherma EHFH03S18D 3V Series Installer's Reference Manual page 212

Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
A.8
[2-09]
Adjust the offset on the measured room temperature
A.8
[2-0A]
Adjust the offset on the measured room temperature
A.8
[2-0B]
What is the required offset on the measured outdoor temp.?
A.8
[2-0C]
What emitter type is connected to the main LWT zone
A.8
[2-0D]
What emitter type is connected to the additional LWT zone?
A.8
[3-00]
Is auto restart of the unit allowed?
A.8
[3-01]
--
A.8
[3-02]
--
A.8
[3-03]
--
A.8
[3-04]
--
A.8
[3-05]
--
A.8
[3-06]
What is the maximum desired room temperature in heating?
A.8
[3-07]
What is the mimimum desired room temperature in heating?
A.8
[3-08]
What is the maximum desired room temperature in cooling?
A.8
[3-09]
What is the minimum desired room temperature in cooling?
A.8
[4-00]
What is the BUH operation mode?
A.8
[4-01]
Which electric heater has priority?
A.8
[4-02]
Below which outdoor temperature is heating allowed?
A.8
[4-03]
--
A.8
[4-04]
Is the pump allowed during pipe freeze prevention?
A.8
[4-05]
--
A.8
[4-06]
Emergency
A.8
[4-08]
Which power limitation mode is required on the system?
A.8
[4-09]
Which power limitation type is required?
A.8
[4-0A]
--
A.8
[4-0B]
Automatic cooling/heating changeover hysteresis.
A.8
[4-0D]
Automatic cooling/heating changeover offset.
A.8
[5-00]
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
A.8
[5-01]
What is the equilibrium temperature for the building?
A.8
[5-02]
Space heating priority.
A.8
[5-03]
Space heating priority temperature.
A.8
[5-04]
Set point correction for domestic hot water temperature.
A.8
[5-05]
What is the requested limit for DI1?
A.8
[5-06]
What is the requested limit for DI2?
A.8
[5-07]
What is the requested limit for DI3?
A.8
[5-08]
What is the requested limit for DI4?
A.8
[5-09]
What is the requested limit for DI1?
A.8
[5-0A]
What is the requested limit for DI2?
A.8
[5-0B]
What is the requested limit for DI3?
A.8
[5-0C]
What is the requested limit for DI4?
A.8
[5-0D]
--
A.8
[5-0E]
--
A.8
[6-00]
The temperature difference determining the heat pump ON temperature.
A.8
[6-01]
The temperature difference determining the heat pump OFF temperature.
A.8
[6-02]
--
A.8
[6-03]
--
A.8
[6-04]
--
A.8
[6-05]
--
A.8
[6-06]
--
A.8
[6-07]
--
A.8
[6-08]
What is the hysteresis to be used in reheat mode?
A.8
[6-09]
--
A.8
[6-0A]
What is the desired comfort storage temperature?
A.8
[6-0B]
What is the desired eco storage temperature?
A.8
[6-0C]
What is the desired reheat temperature?
A.8
[6-0D]
What is the desired DHW production type?
(*1) Only applicable for models where cooling is possible
(*2) EHFH03S18D▲3V▼
Range, step
Default value
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
-5~5°C, step: 0,5°C
0°C
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
R/W
0: No
1: Yes
0
1
4
2
1
R/W
18~30°C, step: 0,5°C
30°C
R/W
12~18°C, step: 0,5°C
12°C
R/W
25~35°C, step: 0,5°C
35°C
R/W
15~25°C, step: 0,5°C
15°C
R/W
0: Disabled
1: Enabled
2: Only DHW
R/W
0: None
1: -
2: BUH
R/W
14~35°C, step: 1°C
22°C
3
R/O
0: intermittent pump operation
1: Continuous pump operation
2: OFF
0
R/W
0: Manual
1: Automatic
R/W
0: No limitation
1: Continuous
2: Digital inputs
R/W
0: Current
1: Power
0
R/W
1~10°C, step: 0,5°C
1°C
R/W
1~10°C, step: 0,5°C
3°C
R/W
0: Allowed
1: Not allowed
R/W
-15~35°C, step: 1°C
0°C
R/W
0: Disabled
1: Enabled
R/W
-15~35°C, step: 1°C
0°C
R/W
0~20°C, step: 1°C
10°C
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~50 A, step: 1 A
50 A
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
R/W
0~20 kW, step: 0,5 kW
20 kW
0
1
R/W
2~40°C, step: 1°C
25°C
R/W
0~10°C, step: 1°C
2°C
0
0
0
0
0
0
R/W
2~20°C, step: 1°C
10°C
0
R/W
30~[6-0E]°C, step: 1°C
60°C
R/W
30~min(50, [6-0E])°C, step: 1°C
50°C
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
R/W
0: Reheat only
1: Reheat + sched.
2: Scheduled only
5/8
Installer setting at variance with
default value
Date
Value
4P596814-1B - 2022.09