Daikin ComfortNet DX7TC Service Instructions Manual page 79

Split system heat pumps with r-410a refrigerant blowers, coils, & accessories
Table of Contents

Advertisement

BLOWER PERFORMANCE DATA
HTR kW
^ Factory setting
LOW STAGE
MODEL
MBVC1200
MBVC1600
MBVC2000
^ Factory setting
Locate the blower speed selection DIP switches on the integrated control module. Select the desired "cooling"
speed tap by positioning switches 1 and 2 appropriately. Select the desired "adjust" tap by positioning switches
3 and 4 appropriatly. Refer to the following Dipswitches - Cooling Airflow and Airflow Adjust Taps figure for switch
positions and their corresponding taps. Verify CFM by counting the number of times the green CFM LED blinks.
Thermostat "Fan Only" Mode
During"Fan Only" operations, the CFM output is 30% of the maximum CFM capability.
CFM Trim Adjust
Minor adjustments can be made through the dipswitch combination of 3-4.
MBVC1200*
3
600
5
600
6
635
8
740
10
1000
15
1400
20
NR
21
NR
HIGH STAGE
COOL
COOL
400
600
540
800
670
1000
800
1200
670
1000
800
1200
940
1400
1070
1600
800
1200
1070
1600
1200
1800
1340
2000
Normal*
OFF
ON
3
4
Air flow Adjust Taps (*indicates factory setting)
Dip Switches - Cooling Airflow
and Airflow Adjust Taps
MBVC1600*
MBVC2000*
800
800
800
800
800
800
1000
1000
1000
1200
1500
1500
NR
2000
NR
NR
COOL SELECTION
SWITCHES
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
+10%
-10%
OFF
ON
OFF
ON
3
3
4
4
SWITCH
SWITCH
9
10
ON
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON^
ON^
ADJUST SELECTION
PROFILE SELECTION
SWITCHES
3
4
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Normal
OFF
ON
3
4
SWITCH
11
ON
OFF
ON
OFF
ON
OFF
ON
ON^
SWITCHES
5
6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
79