Summary of Contents for Kohler Mira Sport J03In

  • Page 1 Mira Sport Thermostatic 9.0 and 9.8 kW For SPARES, For Safety! ADVICE or REPAIRS Before installing please call us free or using this shower, on 0800 001 4040 you MUST read this (UK only) guide. Installation and User Guide These instructions must be left with the user 1561659-W2-A...
  • Page 2: Important Safety Information

    Important Safety Information Warning! This shower can deliver scalding temperatures, cause fire, electric shock or other personal injury if not operated, or maintained in accordance with the instructions, warnings and cautions contained in this guide and on the appliance. Please read the important safety information and the operation section of this guide before using the shower.
  • Page 3 DO NOT restrict the water flow from the shower outlet, temporarily bending the shower hose or blocking the shower head, such as placing against your body while in use can cause a very hot shot of water to be discharged. The outlet must not be connected to any tap or fitting other than those specified.
  • Page 4 Only Kohler Mira recommended accessories should be used. DO NOT perform any unspecified modifications, or drill or cut holes in the product other than instructed by this guide.
  • Page 5 DO NOT connect this shower to a Waste Water Heat Recovery System as this may cause unstable or scalding temperatures to be delivered from the shower head. Always check the water temperature is safe before entering the shower. The water supply to this product must be isolated if the product is not to be used for a long period of time.
  • Page 6: Pack Contents

    Pack Contents Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1 x Mira Sport Thermostatic Electric Shower  1 x Olive   1 x Compression Nut   3 x Fixing Screws  ...
  • Page 7: Products Covered

    Products manufactured by Kohler Mira Ltd are designed to be safe provided, that they are installed used and maintained in good working order, in accordance with our instructions and recommendations.
  • Page 8: Specifications

    Specifications Thermostatic Variant Plumbing Sport 9.0 Sport 9.8 Minimum Dynamic Pressure 70 kPa (0.7 bar) Maximum Dynamic Pressure * 500 kPa (5 bar) Minimum Static Pressure 20 kPa (0.2 bar) Maximum Static Pressure * 1000 kPa (10 bar) Maximum Inlet Temperature 30°C Minimum Inlet Temperature 2°C...
  • Page 9 Guarantee For domestic installations, Mira Showers guarantee the Mira product against any defect in materials or workmanship for a period of two years from the date of purchase (shower fittings for one year). For non-domestic installations, Mira Showers guarantee the Mira product against any defect in materials or workmanship for a period of one year from the date of purchase.
  • Page 10: Disposal And Recycling

    Disposal and Recycling End of Product Life Electrical and electronic devices contain a range of materials that can be separated for recycling and used in new products. This product should not be disposed of with your general household waste. When this product has reached the end of its serviceable life, please remove any batteries and take it to a recognised WEEE (Waste Electrical and Electronic Equipment) collection facility such as your local civic amenity site for recycling.
  • Page 11: Installation Requirements

    Installation Requirements Plumbing 1. The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice specified by the local water supply company. 2. DO NOT use any other shower fittings. Only install and use the shower hose and handset provided with this product.
  • Page 12 DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure. 18. A water treatment device should be installed where the water hardness may exceed 200 ppm. Malfunctions caused by excessive limescale formation are not covered by this shower’s guarantee (see back page for details).
  • Page 13 Electrical 1. The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. 2. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
  • Page 14: Installation

    Installation Warning! Turn off the electrical and water supplies before proceeding with the installation of the shower. Remove the three screws that Screws hold the cover on and remove Service the cover. Tunnel Remove the service tunnel. Using the holes in the case, mark the positions of the three fixing Cover holes.
  • Page 15 Determine the direction and route of the incoming water supply: falling (entering the shower from the top), or rising (entering the shower from the bottom). Note: DO NOT use an incoming supply entering the shower directly from the back. Add an elbow to the supply pipe and connect it as a rising or falling supply.
  • Page 16 Connect the inlet supply pipe to the inlet connector using Inlet the compression nut and olive Connector (supplied). Always provide mechanical support when making plumbing connections. Upon Olive completion of the installation ensure connections and back Compression case are not under any stress due to misaligned pipework or Inlet Supply electrical cables.
  • Page 17 Screws E n s u r e t h e e a r t h b o n d i n g c o m p l i e s w i t h r e l e v a n t regulations.
  • Page 18 Commissioning HIGH POWER TEMPERATURE TEMPERATURE Turn temperature control to Turn power control to low. Switch on the electrical supply. the cold position. HIGH COLD 0 - 15 secs Push START/STOP button. POWER POWER Water flows freely within a Turn power control to Eco. few seconds, temperature Light in the button illuminates.
  • Page 19: Operation

    Operation Read the section “Important Safety Information” first. Push the START/STOP button to turn ON the appliance. Light in the button illuminates. Switch on the electrical supply. HIGH POWER POWER Turn the power control to the desired TEMPERATURE TEMPERATURE Adjust temperature as required. See *Important position.
  • Page 20 * Important! For Dual Head Products. Using the overhead shower during winter months may require the desired outlet temperature to be increased. Cooler room temperatures could cause this to be increased too much and operate the cycling thermal switch. If the shower cycles hot/cold ensure shower heads are clean and reduce temperature at control.
  • Page 21 The Effect of Seasonal Changes Incoming mains water temperature is not constant throughout the seasons of the year i.e. cooler during the winter, warmer during the summer. These changes can affect the outlet temperature of the shower, therefore the shower temperature may need to be increased or decreased to maintain the desired showering temperature.
  • Page 22: Fault Diagnosis

    Fault Diagnosis If the malfunction has not been detailed in the fault finding table or it was not possible to correct the malfunction, professional assistance may be required. Any fault diagnosis remedies MUST be carried out by a competent person or contact Mira Customer Services to arrange a service engineer.
  • Page 23 Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Insufficient water supply Showerhead Minimum static pressure pressure for shut off. to ensure shut off and dripping. prevent dripping is 20 kPa (0.2 bar). Note: If other appliances are operating, static pressure may drop below 20 kPa (0.2 bar).
  • Page 24 Start/Stop Power Symptom Light is Control Possible Cause Possible Remedy ON or OFF Position Potential product fault. Contact Mira Customer change in Services. temperature Insufficient mains water Contact local water between company. pressure. Low / Eco / High setting. Water will Potential product fault.
  • Page 25: User Maintenance

    User Maintenance Always read the IMPORTANT SAFETY INFORMATION for your shower. In the event of a malfunction of the shower, a fault finding table is provided in this guide detailing possible causes and remedies that may be carried out by non-qualified personnel.
  • Page 26 Servicing Always read the Important Safety Information before carrying out any servicing or maintenance. Warning! There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part.
  • Page 27: Customer Support

    Cromwell Road, of Kohler Mira Limited. Kohler France S.A.S. Cheltenham, 30 Boulevard de la Bastille, The company reserves the right 75012 Paris, to alter product specifications Gloucestershire GL52 5EP France without notice. 14648 © Kohler Mira Limited, October 2023 1561659-W2-A...