Page 1
WH-ADC0509L3E5UK Subject: Revision of Disassembly and Assembly Instructions Please file and use this supplement manual together with the service manual for Model No. WH-ADC0509L3E5 WH-ADC0509L3E5AN WH-ADC0509L6E5 WH-ADC0509L6E5AN WH-ADC0509L3E5B WH-ADC0509L3E5UK WH-WDG05LE5 WH-WDG07LE5 WH-WDG09LE5 Order No. PAPAMY2303060CE. WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public.
1 Operation and Control 1) P-Q graph for different pump HEX du ty P-Q (AIO L series) Duty: 89 Hex Max Duty: C5 Hex Duty: 78 Hex Min Duty: 46 Hex Water Flow Rate Q[L/min] This condition is under connecting ODU and connecting 5m piping (inner diameter Φ25) between ODU and IDU (AIO).
2 Disassembly and Assembly Instructions To Remove Flow Sensor, Plug and Valve Body 1. Turn the Plug anti-clockwise then remove. 2. Detach the Flow Sensor lead wire. 3. Turn the Valve Body anti-clockwise then remove. 2.2 To Remove Bottle Complete 1.
3 Self-Diagnosis Method 3.1 Abnormal Buffer Tank Sensor (H36) Malfunction Caused: Faulty connector connection. Faulty buffer tank sensor. Faulty indoor sub PCB. Abnormality Judgment: Continue for 5 seconds. For safety reason and to prevent Abnormal buffer tank sensor component brea kdown, always switch Caution off the powerbefore remove and connect the component.