CS-A70KE
Operation Details
4) Automatic Mode Operation
5
| Standard for Determining Operation Mode
Setting Temperature (Standard
+
23°C | Cooling Mode
Cooling Mode
|
Intake air
Soft Dry Mode
Soft Dry Mode
|
20°C
lemiPe iets
Heating Mode
Heating mode
(a) Indoor fan operates at SLo fan speed for 20 seconds.
(b) After judging indoor air temperature, the operation mode is determined and operation continued at the mode
determined.
(c) If indoor intake air is less than 16°C, Heating mode will immediate operate.
(d) After the operation mode has been determined, the mode does not change. However, Soft Dry mode operation
includes Cooling mode operation.
(e) If Automatic Mode operation is started while the air conditioner is operating, operation will continue. If current
operation is in Cooling mode (including the operation which is a part of Soft Dry mode operation), it will be
maintained, for 20 seconds at SLo fan speed. Then, the selected operation mode will continue.
(f)
Room temperature adjustment.
The following are added to the setting temperature specified as above.
Higher
>
+2°C
Standard
>
+0°C
Sleep Mode Auto Operation
I
8 HOURS
———___>|
| Cooling or Soft Dry operation
When you press the SLEEP Mode, the following move-
ment will start to avoid overcooling.
* The fan speed is automatically set to Low.
¢ The setting temperature will be risen by 0.5°C at the
start of
operation and by 0.5°C one hour later.
START
[STOP|
e The operation will stop after 8 hours.
Heating operation
When you press the SLEEP Mode, the following move-
ment will start to avoid overheating.
¢ The fan speed is automatically set to Low or Super Low.
© The setting temperature will be dropped by 2°C at the
start of operation and by 3°C one hour later.
© The operation will stop after 8 hours.