Weber Genesis E-360 Installation Manual page 7

Built-in gas barbecue
Hide thumbs Also See for Genesis E-360:
Table of Contents

Advertisement

Planning the LPG Cylinder
Enclosure
Typical LPG Gas Supply Installation
The LPG cylinder enclosure shall house the included
hose and regulator assembly. The hose and regulator
are required parts of the built-in gas barbecue.
A properly constructed cylinder enclosure meets
the requirements for venting and separation of the
LPG cylinder from a heat source. An LPG cylinder
enclosure shall be ventilated by openings at both the
upper and lower levels of the cylinder. T he surface
inside the cylinder enclosure should be level so that
the LPG cylinder can sit upright. Do not place the LPG
cylinder on its side.
Cylinder compartments shall have permanent
openings ventilating to the outside of the appliance,
and consisting of either—
(a) perforations, uniformly distributed over the height
of the enclosure and with a total free area of not
less than 25% of the sidewall area: or
(b) separate openings at high and low level, such that—
(i) the total free area at high levels not less than
20 000 mm
and is within 125 mm of the top of
2
the cylinder compartment; and
(ii) the total free area low level is not less than
20 000 mm
and—
2
(A) at least 25% of the required area is
within 15 mm of the base of the cylinder
compartment;
(B) the total required area is within 125 mm of
the base of the cylinder compartment area;
and
(C) the opening cannot be obstructed by the
cylinder(s).
NOTE: Contact your local municipality for building codes
regulating outdoor gas barbecue installations. You must
conform to the latest edition of the local and national code
as applicable.
Cylinder Requirements
• Use cylinders with a minimum capacity of 8.5 kg.
LPG Cylinder Access
The area should be kept clear of sharp, jagged or
extremely abrasive surfaces to avoid possible damage
to gas supply lines. Exercise caution when pulling gas
lines through built-in structure.
The LPG cylinder, hose/regulator and bulkhead must
be easily accessible. The LPG cylinder, hose/regulator,
and bulkhead must be easily accessible. The height
of the tank enclosure (1) must be at least 686 mm
(27") from its floor to its ceiling. The width of the door
opening (2) must be at least 385 mm (15") from side
to side. The height of the door opening (3) must be at
least 559 mm (22") from top to bottom.
NOTE: Cylinder enclosure door not included.
DANGER: An LPG cylinder enclosure for
m
a gas cylinder must be built following
the requirements for ventilation, cylinder
retention, and separation of the LPG cylinder
from a heat source. Failure to follow these
guidelines could be dangerous, and could
result in a fire or an explosion causing serious
bodily injury or death and damage to property.
DANGER: Use of any other hose and regulator
m
assembly could be dangerous, and may
not provide adequate gas supply to the gas
barbecue, and could result in a fire or an
explosion causing serious bodily injury or
death and damage to property.
LPG CYLINDER COMPARTMENT
OPENING CLEARANCES
1
1
2
3
GENESIS Burner Valve Orifice Sizes & Consumption Data
Gas Category
I
(30 mbar or 2.8 kPa)
3B/P
2
3
686 mm (27")
385 mm (15")
599 mm (22"))
BURNER VALVE ORIFICE SIZES
360 Models
460 Models
Main Burners 1.04 mm
Main Burners 0.98 mm
Sear Burner 1.02 mm
Sear Burner 0.98 mm
TOTAL CONSUMPTION DATA
360 Models
460 Models
57.5 Mj/h
63.5 Mj/h
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genesis s-360Genesis e-460Genesis s-460

Table of Contents