HARDWARE INSTALLATION GUIDE 1U, 1.5U, and 2U Mid-Mount Rack Kit for Two-Post Racks Supporting XEN-000165, XEN-000175, and XEN-R000292 53-1001273-11 Rev AA August 2019 *53-1001273-11 Rev AA*...
Page 2
Legal Notice Extreme Networks, Inc. reserves the right to make changes in specifications and other information contained in this document and its website without prior notice. The reader should in all cases consult representatives of Extreme Networks to determine whether any such changes have been made.
Getting Help..........................................6 • Providing Feedback to Us....................................7 ® This section discusses the conventions used in this guide, ways to provide feedback, additional help, and other Extreme Networks publications. Conventions This section discusses the conventions used in this guide. Notes, cautions, and warnings Notes, cautions, and warning statements may be used in this document.
Training Extreme Networks offers product training courses, both online and in person, as well as specialized certifications. For more information, visit www.extremenetworks.com/education/. Getting Help If you require assistance, contact Extreme Networks using one of the following methods: 1U, 1.5U, and 2U Mid-Mount Rack Kit for Two-Post Racks...
Providing Feedback to Us Quality is our first concern at Extreme Networks, and we have made every effort to ensure the accuracy and completeness of this document. We are always striving to improve our documentation and help you work better, so we want to hear from you! We welcome all feedback but especially want to know about: •...
Page 8
1U, 1.5U, and 2U Mid-Mount Rack Kit for Two-Post Racks 53-1001273-11 Rev AA...
Introduction Use the following instructions to install a fixed-port device in a mid-mount configuration in a two-post rack using the 1U, 1.5U, and 2U Mid-Mount Kit for Two-Post Racks (XEN-000165, XEN-000175, and XEN-R000292). Observe the following when mounting this device: •...
These handles were not designed to support the weight of the chassis. Time and items required Allow 15 to 30 minutes to complete the installation procedure. The following items are required to install a device using the 1U, 1.5U, or 2U Mid-Mount Kit for Two-Post Racks (XEN-000165, XEN-000175, and XEN-R000292). •...
Attaching the front brackets to the device FIGURE 1 Rack kit parts Bracket, front right and back left Screw, 6-32 x 1/4-in., flathead Phillips (8) Bracket, front left and back right Screw, 10-32 x 5/8-in., panhead Phillips (8) Screw, 8-32 x 5/16-in., panhead Phillips (12) Retainer nut, 10-32 (8) Attaching the front brackets to the device CAUTION...
Attaching the device to a rack Insert 8-32 x 5/16-in. screws through the rest of the holes in the bracket and into the corresponding holes in the device. Repeat step 1 through step 3 to attach the left front bracket to the left side of the device. Tighten all of the 8-32 x 5/16-in.
Attaching the rear brackets to the rack NOTE Do not use the rear brackets for the Extreme Networks 6505, 6510, or 6520 switches. Complete the following steps to attach the rear brackets to the rack. Position the right rear bracket in the right rear of the device as shown in the following figure.
Attaching the rear brackets to the device Adjust the brackets to the rack depth and tighten the screws to a torque of 25 in-lbs (29 cm-kgs). FIGURE 4 Attaching the rear brackets to a rack Bracket, front right Screw, 10-32 x 5/8-in., flathead Phillips Retainer nut, 10-32 Bracket, rear right Attaching the rear brackets to the device...
Page 15
Attaching the rear brackets to the device Tighten all the screws to a torque of 9 in-lbs (10 cm-kgs). FIGURE 5 Attaching the rear brackets to the device Screw, 8-32 x 5/16-in., panhead Phillips 1U, 1.5U, and 2U Mid-Mount Rack Kit for Two-Post Racks 53-1001273-11 Rev AA...