move. 'T'P-6GOR
SERVICE MANUAL
AIWA CO.. LTD. Tokvo, JAPAN
1.
Disassembly
(see Fig.
1).
| Fig. 1 |
(Fig. 2)
The remote
jack is the smallest of the three
jacks coming in a row.
o. Defective
contact
of the remote
jack:
The symptom
typical of this trouble
is that whereas
the set operates with
the microphone plug inserted in'o this
jack and the remote
switch turned on,
the set fails to operate when the plug
is pulled off. Check
if the lead wire
is broken.
b. Defective
contact of push button (Fig. 3):
Such
occurs
when
the segment
plates,
A and
B do
not
come
in
contact with each other even in Play or Rewind
position.
To remedy
this defect, bend
B somewhat
in the direction indicated by the arrow
merk
in Fig. 3.
c. Defective
motor (Fig. 4):
If the reel platform does not revolve in Play or Rewind
position
while yet all other parts are found normal, it indicates the defective
motor,
which
should
be replaced.
Use a screwdriver
to unfasten screw.
Fig. 4
d. No
operation
on
battery
power
supply.
Or very
slow
in re-
volution
speed:
The
above
symptom
indicates
the worn-out
or excessively
weak-
ened
battery, which
must
be replaced
immediately.