Page 2
All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies. ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or...
(approximately 12.5mm), but is NOT protected against liquid intrusion of any kind. CUSTOMER SUPPORT - Contact ELATION Service for any product related service and support needs. Also visit forums.elationlighting.com...
B. For warranty service, send the product only to the Elation Professional factory. All ship- ping charges must be pre-paid. If the requested repairs or service (including parts replace- ment) are within the terms of this warranty, Elation Professional will pay return shipping charges only to a designated point within the United States.
This fixture is a sophisticated piece of electronic equipment. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual. Elation Professional is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
Page 7
S A F E T Y G U I D E L I N E S DO NOT TOUCH the fixture housing during operation. DO NOT shake fixture, and avoid brute force when installing and/or operating fixture. DO NOT operate fixture if the power cord is frayed, crimped, damaged and/or if any of the power cord connectors are damaged or do not fit into the fixture securely with ease.
O V E R V I E W Barndoor Sliding Control Panel Cover Safety Cable Anchor Point Omega Bracket Mounting Holes Adjustable Glare Shield Barndoor Lens Filter Slot and Locking Fuse: & Sliding Lock Thumb Screws T6.3A/250V DMX Out DMX In F F U U S S E E : : T T 6 6 .
Page 9
O V E R V I E W F F U U S S E E : : T T 6 6 . . 3 3 A A / / 2 2 5 5 0 0 V V P P O O W W E E R R O O U U T T P P O O W W E E R R I I N N N N E E T T O O U U T T D D M M X X O O U U T T...
I N S TA L L AT I O N G U I D E L I N E S FLAMMABLE MATERIAL WARNING Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations.
Page 11
I N S TA L L AT I O N G U I D E L I N E S RIGGING Overhead rigging requires extensive experience, including calculating working load limits, knowledge of installation material being used, and periodic safety inspection of all installation material and the fixture, among other things.
Page 12
I N S TA L L AT I O N G U I D E L I N E S MOUNTING THE FIXTURE ON A TRUSS USING CLAMPS WITH OMEGA BRACKET When mounting the fixture to a truss, be sure to secure an appropriately rated professional grade rigging clamp to the included Omega Brackets using an M10 screw fitted through the center hole of the Omega Brackets.
Page 13
I N S TA L L AT I O N G U I D E L I N E S Please note that the designated safety cable rigging point is the only safe location to attach a safety cable! Never attach a safety cable to the mounting clamp bracket!
Page 14
If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury. The Elation KL CYC L can be truss mounted in all positions. FALLING FIXTURES CAN CAUSE SEVERE INJURY OR SERIOUS EQUIPMENT DAMAGE! FOR THIS REASON, FIXTURES SHOULD BE INSTALLED AND INSPECTED ONLY BY QUALIFIED PERSONNEL.
A R T- N E T | S A C N C O N N E C T I O N ART-NET | sACN CONNECTION When connecting fixture to a network switch to control multiple devices, a Gigabit Ethernet Switch that supports IGMP (Internet Group Management Protocol) is required. Using a Gigabit Ethernet Switch that does not support IGMP can cause erratic behavior of all connected devices to the switch.
ACCESSORY OPERATION: ADJUSTABLE GLARE SHIELD Untighten 3x Thumb Screws, and position the Glare Shield to the desired height. Tighten 3x Thumb Screws...
R E M O T E D E V I C E M A N A G E M E N T ( R D M ) NOTE: In order for RDM to work properly, RDM enabled equipment must be used throughout the entire system, including DMX data splitters and wireless systems.
NOTE: The unit comes with a battery so that the menu options can be changed or setup without the need to plug the unit into power. AN ELATION C-LOADER II CAN ALSO BE USED TO UPDATE THE FIXTURE TO THE LATEST SOFTWARE. To order this device, please contact Elation Support for further details..
Page 20
S YS T E M M E N U MAIN OPTIONS / VALUES (Default Settings in BOLD) MENU DMX Address 001 - 512 1CH Dimmer 4CH RGB 4CH CCT 4CH HSI 12CH HSI Extended 11CH CMY DMX Mode 16CH CMY Extended 13CH Standard 20CH Extended 19CH Standard 2 Zone...
Page 21
S YS T E M M E N U MAIN OPTIONS / VALUES (Default Settings in BOLD) MENU Current Run Time Time Total Run Time Last Run Time Current Temperature Max Resettable DMX Values Green Product IDs RDM UID Error Logs Fixture Errors Software Version Vx.x Update Firmware On / Off...
C Y C L O R A M A E D G E L I G H T F E AT U R E With the understanding and intention that the KL CYC FC can excel in a footlight or foot ramp application, we aimed to integrate additional functions to enhance the fixture’s capabilities and offer a distinctive safety feature.
D I M M E R C U R V E S A N D D I M M E R M O D E S DIMMER 100% Time (ms) 0 Sec Rise Time Down Time 0 sec Fade Time 1 sec Fade Time Dimming Curve Ramp Effect...
D M X T R A I T S Std. Ext. Ext. Ext. Dimmer Std. Ext. Default EXT. EXT. 2 Zone 2 Zone 4 Zone 4 Zone Function Snap 1Ch. 4Ch. 4Ch. 4Ch. 11Ch. 13Ch. 20Ch. Values Value 12Ch. 16Ch. 19Ch.
Page 25
D M X T R A I T S Std. Ext. Ext. Ext. Dimmer Std. Ext. Snap Default EXT. EXT. 2 Zone 2 Zone 4 Zone 4 Zone Function 1Ch. 4Ch. 4Ch. 4Ch. 11Ch. 13Ch. 20Ch. Values Value 12Ch. 16Ch. 19Ch.
Page 26
D M X T R A I T S Std. Ext. Ext. Ext. Dimmer Std. Ext. Default EXT. EXT. 2 Zone 2 Zone 4 Zone 4 Zone Function Snap 1Ch. 4Ch. 4Ch. 4Ch. 11Ch. 13Ch. 20Ch. Values Value 12Ch. 16Ch. 19Ch.
Page 27
D M X T R A I T S Std. Ext. Ext. Ext. Dimmer Std. Ext. Default EXT. EXT. 2 Zone 2 Zone 4 Zone 4 Zone Function Snap 1Ch. 4Ch. 4Ch. 4Ch. 11Ch. 13Ch. 20Ch. Values Value 12Ch. 16Ch. 19Ch.
Page 28
D M X T R A I T S Std. Ext. Ext. Ext. Dimmer Std. Ext. Snap Default EXT. EXT. 2 Zone 2 Zone 4 Zone 4 Zone Function 1Ch. 4Ch. 4Ch. 4Ch. 11Ch. 13Ch. 20Ch. Values Value 12Ch. 16Ch. 19Ch.
C O LO R T E M P E R AT U R E DMX VALUE COLOR TEMPERATURE (K) DMX VALUE COLOR TEMPERATURE (K) 6300 2400 2500 6400 2600 6500 2700 6600 2800 6700 2900 6800 3000 6900 3100 7000 3200 7100 3300...
V I R T U A L G E L S WAT C H B O O K C O L O R VALUE FILTER # COLOR VALUE FILTER # COLOR Pale Yellow Mauve Straw Medium Purple Gold Tint Lavender Spring Yellow Palace Blue Medium Yellow...
E R R O R C O D E S Error Codes subject to change without notice ERROR CODES DESCRIPTION Temp Error This message appears when there is a heating error. Init Error This message appears when there is an initial startup error. P I X E L G R O U P I N G...
Regular inspections are recommended to ensure proper function and extended life. There are no user serviceable parts inside this fixture. Please refer all service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from an authorized Elation dealer.
S P E C I F I C AT I O N S SOURCE 180W RGBMA LED Array 30,000 Hour Average LED Life* *May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control and Dimming. PHOTOMETRIC DATA 6300+ Total Lumen Output CRI 92...
D I M E N S I O N A L D R AW I N G S Drawings not to scale.
Page 35
O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM KLC013 1237000281 Elation KL CYC L TRIGGER CLAMP 1741000032 Heavy Duty Wrap Around Hook Style Clamp PDJ010 1621000162 10”...