Summary of Contents for Gigabyte Dual 2000W 80 PLUS Titanium

  • Page 1 S183-SH0-AAJ1/ABJ1 S183-SH0-AAV1/ABV1 Storage Server 4th/5th Gen Intel® Xeon® Scalable 1U DP 32-Bay E1.S NVMe Dual 2000W 80 PLUS Titanium redundant power supply (AAJ1/ABJ1) Dual 1600W 80 PLUS Titanium redundant power supply (AAV1/ABV1) User Manual Rev. 1.0...
  • Page 2 For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller portal: http://reseller.b2b.gigabyte.com For further technical assistance, please contact your GIGABYTE representative or visit https://esupport.gigabyte.com/ to create a new support ticket For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email: server.grp@gigabyte.com...
  • Page 3 Conventions The following conventions are used in this user's guide: NOTE! Pieces of additional information related to the current topic. CAUTION! Precautionary measures to avoid possible hardware or software problems. WARNING! Alerts to any damage that might result from doing or not doing specific actions.
  • Page 4 Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING! To reduce the risk of electric shock or damage to the equipment: • Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
  • Page 5 Electrostatic Discharge (ESD) CAUTION! ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE, PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT- TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER WHEN HANDLING PARTS.
  • Page 6 Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that can be gripped with fin-gertips or with a pair of fine needle nosed pliers. If the jumpers do not have such a tab, take care when us- ing needle nosed pliers to remove or install a jumper;...
  • Page 7: Table Of Contents

    Table of Contents Chapter 1 Hardware Installation ...................10 Installation Precautions .................. 10 Product Specifications ..................11 System Block Diagram ................... 15 Chapter 2 System Appearance ..................16 Front View ...................... 16 Rear View ....................... 17 Front Panel LEDs and Buttons ............... 18 RoT LEDs .......................
  • Page 8 5-2-2 Serial Port Console Redirection ................52 5-2-3 SIO Configuration ....................55 5-2-4 PCI Subsystem Settings ..................56 5-2-5 USB Configuration ....................58 5-2-6 Network Stack Configuration ..................59 5-2-7 Post Report Configuration ..................60 5-2-8 NVMe Configuration ....................61 5-2-9 Chipset Configuration .....................62 5-2-10 Tls Auth Configuration ....................63 5-2-11 iSCSI Configuration ....................64 5-2-12 Intel(R) i350 Gigabit Network Connection ..............65 5-2-13 VLAN Configuration ....................67...
  • Page 9 This page intentionally left blank - 9 -...
  • Page 10: Chapter 1 Hardware Installation

    Chapter 1 Hardware Installation Installation Precautions The motherboard/system contain numerous delicate electronic circuits and components which can become damaged as a result of electrostatic discharge (ESD). Prior to installation, carefully read the service guide and follow these procedures: • Prior to installation, do not remove or break motherboard S/N (Serial Number) sticker or warranty sticker provided by your dealer.
  • Page 11: Product Specifications

    Product Specifications NOTE: We reserve the right to make any changes to the product specifications and product-related information without prior notice. System Security Server Socket Operating Properties Š 1U Dimension Š 438 (W) x 43.5 (H) x 730(D) mm System fan Power Supply Š...
  • Page 12 RAID Optional compatible RAID Cards: Š NVMe/NVMe-oF RAID Cards with SupremeRAID™ by Graid Technology Š RAID Card models: SR-1000-FD32, SR-1010-FD32 Š Support RAID 0/1/5/6/10 Expansion Slot Riser Card CRSD013: 1 x PCIe x16 (Gen5 x16) FHHL slot, from CPU_1 Š Riser Card CRSD022: 1 x PCIe x16 (Gen5 x16 or x8) FHHL slot, from CPU_0 Š...
  • Page 13 ocket Security Server Operating Properties System fan Power Supply Power Supply S183-SH0-AAJ1/S183-SH0-ABJ1 1+1 2000W (240V) 80 PLUS Titanium redundant power supplies AC Input: Š 100-127V~/ 12A, 50-60Hz Š 200-240V~/ 10A, 50-60Hz DC Input: Š 40Vdc/ 10A DC Output: Š Max 1000W/ 100-127V~ Š...
  • Page 14 System Š Aspeed® AST2600 management controller Management Š GIGABYTE Management Console (AMI MegaRAC SP-X) web interface Š Dashboard Š HTML5 KVM Š Sensor Monitor (Voltage, RPM, Temperature, CPU Status …etc.) Š Sensor Reading History Data Š FRU Information Š SEL Log in Linear Storage / Circular Storage Policy Š...
  • Page 15: System Block Diagram

    System Block Diagram E1.S E1.S E1.S E1.S E1.S E1.S E1.S E1.S 32-bay E1.S Gen5 NVMe CPU0 CPU1 4 x UPI 16/20 GT/s 4th/5th Gen Intel Xeon 4th/5th Gen Intel Xeon Scalable processors Scalable processors (LGA4677 Socket) (LGA4677 Socket) 8-Channel DDR5, 16 x DIMMs 8-Channel DDR5, 16 x DIMMs Up to 5600MHz (1DPC), 4400MHz (2DPC) Up to 5600MHz (1DPC), 4400MHz (2DPC)
  • Page 16: Chapter 2 System Appearance

    Chapter 2 System Appearance Front View Description USB 3.2 Gen1 Port Front Panel LEDs and Buttons EDSFF E1.S SSD Bay Note! Drives with green latches support NVMe. • Refer to section 2-3 Front Panel LEDs and Buttons for a detailed description of the function of the LEDs.
  • Page 17: Rear View

    Rear View SLOT3 SLOT2 PSU2 PSU1 SLOT1 1 2 3 4 Description Mini DP Port USB 3.2 Gen1 Port x 2 GbE LAN Port x 2 Server Management LAN Port PCIe Card Slot PCIe Card Slot • Refer to section 2-5 Rear System LAN LEDs for a detailed description of the function of the LEDs.
  • Page 18: Front Panel Leds And Buttons

    Front Panel LEDs and Buttons No. Name Color Status Description Green Indicates the system is powered on. Power button with LED System is not powered on or in ACPI S5 state (power off) Blue System identification is active. ID Button with (Note) System identification is disabled.
  • Page 19: Rot Leds

    RoT LEDs ID LED Status LED LED on Front panel (Note5) ID LED Status LED EC Firmware (FW) Authentication fail or not exit EC FW is broken or not exit (Note1) Authenticating/Recovering BMC/BIOS Images Authenticating Images Blinks Blue Blinks Green Recovering BMC Active Flash 4 times per second 4 times per second...
  • Page 20 Active Flash Authentication (AUTH) Fail Blinks Blue Blinks Green BMC : AUTH Fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Amber BIOS : AUTH fail (Note2) 1 time per second 1 time per second Blinks Blue Blinks Green 2 times per second 2 times per second...
  • Page 21: Rear System Lan Leds

    Rear System LAN LEDs Name Color Status Description Yellow 1 Gbps data rate 1GbE Speed Green 100 Mbps data rate 10 Mbps data rate Link between system and network or no access Green 1GbE Link / Blink Data transmission or reception is occurring. Activity LED No data transmission or reception is occurring.
  • Page 22: Power Supply Unit Led

    Power Supply Unit LED NOTE! The power supply may be vary based on the system configuration. PSU LED State Description No AC power to all power supplies 1Hz Green Blinking AC present / only standby on / Cold redundant mode 2Hz Green Blinking Power supply firmware updating mode AC cord unplugged or AC power lost;...
  • Page 23: Storage Led

    Storage LED NVMe HDD Present RAID SKU Color Locate Rebuilding HDD Access Fault (No Access) No RAID NVMe LED configuration (On NVMe Amber ON (*1) (via HBA, ICH) Module) RAID configuration (via HW RAID NVMe LED Amber BLINK Alternately Card or SW RAID Card) NOTE: (*1) Depends on HBA/Utility Spec...
  • Page 24: Chapter 3 System Hardware Installation

    Chapter 3 System Hardware Installation Pre-installation Instructions Computer components and electronic circuit boards can be damaged by discharges of static electricity. Working on computers that are still connected to a power supply can be extremely dangerous. Follow the simple guidelines below to avoid damage to your computer or injury to yourself.
  • Page 25: Removing And Installing The Chassis Cover

    Removing and Installing the Chassis Cover Before you remove or install the system cover • Make sure the system is not turned on or connected to AC power. Follow these instructions to remove the chassis cover: Unlock the plastic handle and pull the grip handle to open the panel cover. Slide the cover to the rear of the system and then remove the cover in the direction indicated by the arrow.
  • Page 26: Installing The Edsff Ssd

    Installing the EDSFF SSD Read the following guidelines before you begin to install the EDSFF SSD: • Take note of the drive tray orientation before sliding it out. • The tray will not fit back into the bay if inserted incorrectly. •...
  • Page 27: Removing And Installing The Fan Duct

    Removing and Installing the Fan Duct Follow these instructions to remove the fan duct: Remove the two screws securing the fan duct. Lift up to remove the fan duct. To reinstall the fan duct, align the fan duct with the guiding groove. Push down the fan duct until it is firmly seated on the system.
  • Page 28: Removing And Installing The Heat Sink

    Removing and Installing the Heat Sink Read the following guidelines before you begin to install the heat sink: • Always turn off the computer and unplug the power cord from the power outlet before installing the heat sink to prevent hardware damage. •...
  • Page 29: Installing The Cpu And Heat Sink

    Installing the CPU and Heat Sink Read the following guidelines before you begin to install the CPU: • Make sure that the motherboard supports the CPU. • Always turn off the computer and unplug the power cord from the power outlet before installing the CPU to prevent hardware damage.
  • Page 30 Carrier Types used for Package Types Package Type Xeon® SP XCC Xeon® SP MCC Xeon® SP+HBM Carrier Code NOTE! • The carrier code is marked on each carrier and matches a code laser marked on to the IHS(Integrated Heat Spreader) to ensure the right parts are used together. •...
  • Page 31: Removing And Installing Memory

    Removing and Installing Memory Read the following guidelines before you begin to install the memory: • Make sure that the motherboard supports the memory. It is recommended that memory of the same capacity, brand, speed, and chips be used. • Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage.
  • Page 32: Removing And Installing A Memory Module

    3-6-2 Removing and Installing a Memory Module Before installing a memory module, make sure to turn off the computer and unplug the power cord from the power outlet to prevent damage to the memory module. Be sure to install DDR5 DIMMs on to this motherboard.
  • Page 33: Processor And Memory Module Matrix Table

    3-6-4 Processor and Memory Module Matrix Table Memory Q’ty CPU0 CPU1 for each CPU 1 DIMM 2 DIMM 4 DIMM 6 DIMM 8 DIMM 12 DIMM 16 DIMM System Hardware Installation - 33 -...
  • Page 34: Removing And Installing The Pcie Card

    Removing and Installing the PCIe Card • Voltages can be present within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. Ensure that the system is powered off and all power sources have been disconnected from the server prior to installing a PCIe card.
  • Page 35: Removing And Installing The Power Supply

    Removing and Installing the Power Supply Follow these instructions to replace the power supply: Flip up and then grasp the power supply handle. Press the retaining clip on the right side of the power supply unit in the direction indicated. Pull out the power supply unit using the handle.
  • Page 36: Cable Routing

    Cable Routing Motherboard: FP_2 Front Panel LEDs and Buttons Cable Front IO Board: CON_FP1 System Hardware Installation - 36 -...
  • Page 37 E1_PWR1 E1_PWR2 E1_PWR4 E1_PWR3 Motherboard (Rear): E1_PWR1 Motherboard (Front): E1_PWR3 Storage Power Cable Motherboard (Rear): E1_PWR2 Motherboard (Front): E1_PWR4 System Hardware Installation - 37 -...
  • Page 38 A1: Motherboard Motherboard: E1S_A1 E1S_B1 Storage: U2_0 Storage: U2_0 NVMe 4-5 NVMe 20-23 Cable Cable Motherboard: Motherboard: E1S_A2 E1S_B2 Storage: U2_0 Storage: U2_0 System Hardware Installation - 38 -...
  • Page 39 Motherboard: Motherboard: PCIE_A1 PCIE_B1 Riser Slot: Riser Slot: Top Connector: Top Connector: PCIE_A1 PCIE_B1 Bottom Connector: Bottom Connector: PCIE_A2 PCIE_B2 System System Rear Side Rear Side Motherboard: Motherboard: PCIe Cable PCIe Cable PCIE_A2 PCIE_B2 Riser Slot: Riser Slot: Top Connector: Top Connector: PCIE_A1 PCIE_B1...
  • Page 40 Motherboard (Rear): DMI_PCH0 DMI Signal Cable Motherboard (Front): DMI_CPU0 System Hardware Installation - 40 -...
  • Page 41: Chapter 4 Motherboard Components

    Chapter 4 Motherboard Components Motherboard Components 10 11 12 13 CPU1 CPU0 Item Description 2 x 5 Pin 12V Power Connector EDSFF E1.S Connector 2 x 5 Pin 12V Power Connector MCIO Connector (DMI_CPU0) MCIO Connector (E1S_A1/PCIe Gen5 x8) MCIO Connector (E1S_A2/PCIe Gen5 x8) 2 x 5 Pin 12V Power Connector Riser Connector (M2_0/Proprietary) Riser Connector (PWRCON/Proprietary)
  • Page 42 Item Description TPM Module Connector (SPI Interface) Riser Connector (PWRCON/Proprietary) Riser Connector (M2_1/Proprietary) 2 x 5 Pin 12V Power Connector MCIO Connector (PCIE_B1/PCIe Gen5 x8) MCIO Connector (PCIE_B2/PCIe Gen5 x8) MCIO Connector (E1S_B2/PCIe Gen5 x8) MCIO Connector (E1S_B1/PCIe Gen5 x8) MCIO Connector (PCIE_A1/PCIe Gen5 x8) MCIO Connector (PCIE_A2/PCIe Gen5 x8) System Battery...
  • Page 43: Jumper Settings

    Jumper Settings Default Clear CMOS CLR_CMOS Enable CPU1 CPU0 HSMB_SEL BIOS defined PMBUS_SEL BIOS defined Stop initial power on S3_MASK Normal [Default] when BMC is not ready DP_PLD CPLD debug mode Normal [Default] ME_UPDATE Force ME update Normal [Default] BIOS_PWD Clear supervisor password Normal [Default] BIOS_RCVR...
  • Page 44: G-Sc Module

    G-SC Module 4-3-1 CDCR112 BMC1 BMC2 BIOS2 BIOS1 Item Description 10/100/1000 Server Management LAN Port 1GbE LAN Port #2 1GbE LAN Port #1 USB 3.2 Gen1 Port x 2 Mini DP Port Motherboard Components - 44 -...
  • Page 45: Chapter 5 Bios Setup

    Chapter 5 BIOS Setup BIOS (Basic Input and Output System) records hardware parameters of the system in the EFI on the motherboard. Its major functions include conducting the Power-On Self-Test (POST) during system startup, saving system parameters, loading the operating system etc. The BIOS includes a BIOS Setup program that allows the user to modify basic system configuration settings or to activate certain system features.
  • Page 46  Main This setup page includes all the items of the standard compatible BIOS.  Advanced This setup page includes all the items of AMI BIOS special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.) ...
  • Page 47: The Main Menu

    The Main Menu Once you enter the BIOS Setup program, the Main Menu (as shown below) appears on the screen. Use arrow keys to move among the items and press <Enter> to accept or enter other sub-menu. Main Menu Help The on-screen description of a highlighted setup option is displayed on the bottom line of the Main Menu.
  • Page 48 Parameter Description BIOS Information Project Name Displays the project name information. Project Version Displays version number of the BIOS setup utility. Build Date and Time Displays the date and time when the BIOS setup utility was created. BMC Information (Note1) BMC Firmware Version Displays BMC firmware version information.
  • Page 49 Parameter Description Memory Frequency Displays the frequency information of the installed memory. Onboard LAN Information (Note3) LAN# MAC Address Displays LAN MAC address information. System Date Sets the date following the weekday-month-day-year format. System Time Sets the system time following the hour-minute-second format. (Note3) The number of LAN ports listed will depend on the motherboard / system model.
  • Page 50: Advanced Menu

    Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components. Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 50 -...
  • Page 51: Trusted Computing

    5-2-1 Trusted Computing Parameter Description Configuration Enable/Disable BIOS support for security device. OS will not show security device. TCG EFI protocol and INT1A interface will not be TPM v1.2 Support available. Options available: Disable, Enable. Default setting is Enable. BIOS Setup - 51 -...
  • Page 52: Serial Port Console Redirection

    5-2-2 Serial Port Console Redirection Parameter Description Console redirection enables the users to manage the system from a COM1 Console remote location. Redirection (Note) Options available: Enabled, Disabled. Default setting is Disabled. Press [Enter] to configure advanced items. Please note that this item is configurable when COM1 Console Redirection is set to Enabled.
  • Page 53 Parameter Description Parity Š – A parity bit can be sent with the data bits to detect some transmission errors. – Even: parity bit is 0 if the num of 1's in the data bits is even. – Odd: parity bit is 0 if num of 1's in the data bits is odd. –...
  • Page 54 Parameter Description Serial Port for Out-of-Band Management / Windows EMS console redirection allows the user to configure Console Redirection Emergency Management Settings to support Out-of-Band Serial Port management. Services (EMS) Console Options available: Enabled, Disabled. Default setting is Disabled. Redirection (Note) Press [Enter] to configure advanced items.
  • Page 55: Sio Configuration

    5-2-3 SIO Configuration Description Parameter Displays the AMI SIO driver version information. AMI SIO Driver Version Super IO Chip Logical Device(s) Configuration Press [Enter] to configure advanced items. Use This Device Š – When set to Enabled allows you to configure the serial port settings. When set to Disabled, displays no configuration for the serial port.
  • Page 56: Pci Subsystem Settings

    5-2-4 PCI Subsystem Settings BIOS Setup - 56 -...
  • Page 57 Parameter Description PCI Bus Driver Version Displays the PCI Bus Driver version information. When enabled, this setting will initialize the device expansion SLOT_# I/O ROM ROM for the related PCI-E slot. (Note1) Options available: Enabled, Disabled. Default setting is Enabled. SLOT_# Lanes Change the PCIe lanes.
  • Page 58: Usb Configuration

    5-2-5 USB Configuration Parameter Description USB Configuration USB Devices: Displays the USB devices connected to the system. Enable/Disable the XHCI (USB 3.0) Hand-off support. XHCI Hand-off Options available: Enabled, Disabled. Default setting is Enabled. USB Mass Storage Driver Enable/Disable the USB Mass Storage Driver Support. Support Options available: Enabled, Disabled.
  • Page 59: Network Stack Configuration

    5-2-6 Network Stack Configuration Parameter Description Enable/Disable the UEFI network stack. Network Stack Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 PXE feature. Ipv4 PXE Support Options available: Enabled, Disabled. Default setting is Enabled. Enable/Disable the Ipv4 HTTP feature. Ipv4 HTTP Support Options available: Enabled, Disabled.
  • Page 60: Post Report Configuration

    5-2-7 Post Report Configuration Parameter Description Post Report Configuration Error Message Report Enable/Disable the POST Error Message support. Post Error Message Options available: Enabled, Disabled. Default setting is Enabled. Halt On Options available: No Error, All Error. Default setting is No Error. BIOS Setup - 60 -...
  • Page 61: Nvme Configuration

    5-2-8 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system. Options available: BIOS Build-In, NVMe Device. Default setting is BIOS NVMe OPROM Select Build-In. BIOS Setup - 61 -...
  • Page 62: Chipset Configuration

    5-2-9 Chipset Configuration Parameter Description Defines the power state to resume to after a system shutdown that is due to an interruption in AC power. When set to Last State, the system will return to the active power state prior to shutdown. When set to Restore on AC Power Loss (Note1) Power Off, the system remains off after power shutdown.
  • Page 63: Tls Auth Configuration

    5-2-10 Tls Auth Configuration Parameter Description Press [Enter] for configuration of advanced items. Enroll Cert Š – Press [Enter] to enroll a certificate • Enroll Cert Using File • Cert GUID Server CA Configuration Input digit character in 1111111-2222-3333-4444-1234567890ab format. –...
  • Page 64: Iscsi Configuration

    5-2-11 iSCSI Configuration Parameter Description Press [Enter] configure advanced items. Attempt Priority Š Attempt Priority – Use arrow keys to select the attempt, then press +/- keys to move the attempt up/down in the attempt order list. Commit Changes and Exit Š...
  • Page 65: Intel(R) I350 Gigabit Network Connection

    5-2-12 Intel(R) i350 Gigabit Network Connection BIOS Setup - 65 -...
  • Page 66 Description Parameter Press [Enter] to configure advanced items. Link Speed Š – Allows for automatic link speed adjustment. – Options available: Auto Negotiated, 10 Mbps Half, 10 Mbps Full, 100 Mbps Half, 100 Mbps Full. Default setting is Auto Negotiated. Wake On LAN NIC Configuration Š...
  • Page 67: Vlan Configuration

    5-2-13 VLAN Configuration Parameter Description Press [Enter] to configure advanced items. Create new VLAN Š VLAN ID Š – Sets VLAN ID for a new VLAN or an existing VLAN. – Press the <+> / <-> keys to increase or decrease the desired values. –...
  • Page 68: Driver Health

    5-2-14 Driver Health Parameter Description Driver Health Displays driver health status of the devices/controllers if installed BIOS Setup - 68 -...
  • Page 69: Chipset Menu

    Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub(PCH). Select a submenu item, then press <Enter> to access the related submenu screen. BIOS Setup - 69 -...
  • Page 70 5-3-1 Processor Configuration BIOS Setup - 70 -...
  • Page 71: Processor Configuration

    Description Parameter Processor Configuration Press [Enter] to configure advanced items. CPU Socket 0/1 Configuration Š – Core Disable Bitmap(Hex) • Number of Cores to enable. 0 means all cores. FFFFFFF Pre-Socket Configuration means to disable all cores. The maximum value depends on the number of CPUs available.
  • Page 72 Description Parameter Enable/Disable memory encryption (TME). Memory Encryption (TME) (Note) Options available: Enabled, Disabled. Default setting is Disabled. Total Memory Encryption Options available: Enabled, Disabled. Default setting is Disabled. Multi-Tenant (TME-MT) Press [Enter] to configure advanced items. Provision S3M CFR Š...
  • Page 73: Common Refcode Configuration

    5-3-2 Common RefCode Configuration Parameter Description Common RefCode Configuration Divide physical NUMA nodes into evenly sized virtual NUMA nodes in ACPI table. This may improve Windows performance on CPUs Virtual Numa with more than 64 logical processors. Options available: Enable, Disable. Default setting is Disable. BIOS Setup - 73 -...
  • Page 74: Upi Configuration

    5-3-3 UPI Configuration Description Parameter Press [Enter] to configure advanced items. UPI Status Š – Press [Enter] to view the Uncore status. Link Frequency Select Š – Selects the UPI link frequency. – Options available: 12.8GT/s, 14.4GT/s, 16.0GT/s, Auto, Use Per Link Setting.
  • Page 75 Description Parameter MMIO High Granularity Size Š – Selects the allocation size used to assign mmioh resources. – Options available: 1G, 4G, 16G, 64G, 256G, 1024G. Default setting is UPI General Configuration 64G. (continued) Clock Modulation Enabled Š – Options available: Disable, Enable, Auto. Default setting is Auto. BIOS Setup - 75 -...
  • Page 76: Memory Configuration

    5-3-4 Memory Configuration Description Parameter Integrated Memory Controller (iMC) When set to Enable, the system enforces Plan Of Record restrictions for DDR frequency programming. Enforce DDR Memory Frequency POR Options available: POR, Disable. Default setting is POR. Configures the maximum memory frequency. If Enforce POR is disabled, user will be able to run at higher frequencies than the Memory Frequency memory support (limited by processor support).
  • Page 77 Description Parameter Enable/Disable Assert ADR on S5. Assert ADR on S5 Options available: Enabled, Disabled. Default setting is Disabled. Auto is the detected SPD value and use it, otherwise use BIOS Build-in. Get Memory Timing Options available: Auto, BIOS Build-in. Default setting is BIOS Build-in. Press [Enter] to view memory topology with DIMM population Memory Topology information.
  • Page 78 Description Parameter Leaky bucket time window based interface Hour Š – Leaky bucket time window based interface hour used for DDR (0-24). – Press the <+> / <-> keys to increase or decrease the desired values. Leaky bucket time window based interface Minute Š...
  • Page 79: Iio Configuration

    5-3-5 IIO Configuration Description Parameter IIO Configuration Press [Enter] to configure advanced items. ® Intel VT for Directed I/O Š – Enable/Disable the Intel VT for Directed I/O (VT-d) support function by reporting the I/O device assignment to VMM through DMAR ACPI Tables.
  • Page 80 Description Parameter Interrupt Remapping Š – Enable/Disable the interrupt remapping support function. – Options available: Auto, Enable, Disable. Default setting is Auto x2APIC Opt Out Š – Options available: Enable, Disable. Default setting is Disable. Pre-boot DMA Protection Š – Options available: Enable, Disable. Default setting is Disable. Press [Enter] to configure advanced items.
  • Page 81: Advanced Power Management Configuration

    5-3-6 Advanced Power Management Configuration Description Parameter Press [Enter] to configure advanced items. SpeedStep (Pstates) Š – Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor load. – Options available: Enable, Disable. Default setting is Enable. CPU P State Control Turbo Mode Š...
  • Page 82 Description Parameter Press [Enter] to configure advanced items. Enable Monitor MWAIT Š – Allows Monitor and MWAIT instructions. – Options available: Disable, Enable, Auto. Default setting is Auto. CPU C6 Report Š CPU C State Control – Enable/Disable CPU C6(ACPI C3) report to OS. –...
  • Page 83: Pch Configuration

    5-3-7 PCH Configuration Description Parameter PCH-IO Configuration Press [Enter] to configure advanced items. SATA Configuration Š – Enable/Disable SATA controller. – Options available: Enabled, Disabled. Default setting is Enabled. SATA Mode Selection Š – Configures on chip SATA type. – AHCI Mode: When set to AHCI, the SATA controller enables its AHCI functionality.
  • Page 84 Description Parameter Port 0/1/2/3/4/5/6/7 Š – Enable/Disable Port 0/1/2/3/4/5/6/7 device. – Options available: Enabled, Disabled. Default setting is Enabled. Hot Plug (for Port 0/1/2/3/4/5/6/7) SATA And RST Š – Enable/Disable HDD Hot-Plug function. Configuration/ – Options available: Enabled, Disabled. Default setting is Enabled. tSATA Controller And RST Spin Up Device (for Port 0/1/2/3/4/5/6/7) Configuration (continued)
  • Page 85: Miscellaneous Configuration

    5-3-8 Miscellaneous Configuration Description Parameter Miscellaneous Configuration Selects the active video type. Options available: Auto, Onboard Device, PCIE Device, Specific PCIE Active Video Device. Default setting is Auto. Enables Spread spectrum - only affects external clock generator. Options available: SSC Off, SSC = -0.3%, SSC = -0.5%, Hardware. External SSC - CK440 Default setting is SSC Off.
  • Page 86: Server Me Configuration

    5-3-9 Server ME Configuration Parameter Description General ME Configuration Oper. Firmware Version Displays the operational firmware version. ME Firmware Status #1/#2 Displays ME Firmware status information. Current State Displays ME Firmware current status information. Error Code Displays ME Firmware status error code. Recovery Cause Displays ME Firmware recovery cause.
  • Page 87: Runtime Error Logging Settings

    5-3-10 Runtime Error Logging Settings Description Parameter Runtime Error Logging Enable/Disable system error logging function. System Errors Options available: Enable, Disable. Default setting is Enable. Enable/Disable software injection error logging function. S/W Error Injection Support Options available: Enable, Disable. Default setting is Disable. Press [Enter] to configure advanced items.
  • Page 88 Description Parameter Press [Enter] to configure advanced items. PCIE Error Š – Enable/Disable PCIE error. – Options available: Enable, Disable. Default setting is Disable. Uncorrected Error (Note) Š – Enables and escalates Uncorrectable/Recoverable Errors to error pins. – Options available: Enable, Disable. Default setting is Enable. Fatal Error Enable (Note) Š...
  • Page 89: Power Policy

    5-3-11 Power Policy Description Parameter Selects a Power Policy Quick Setting. Options available: Standard, Best Performance, Energy Efficient. Default Power Policy Quick Settings setting is Standard. Conventional Intel SpeedStep Technology switches both voltage and frequency in tandem between high and low levels in response to processor SpeedStep (Pstates) load.
  • Page 90 Description Parameter Enables Logical processor (Software Method to Enable/Disable Logical Processor threads). Enable LP [Global] Options available: ALL LPs, Single LP. Default setting is ALL LPs. Options available: Enable, Disable. Default setting is Enable. Hardware Prefetcher Options available: Enable, Disable. Default setting is Enable. Adjacent Cache Prefetch Options available: Enable, Disable.
  • Page 91: Server Management Menu

    Server Management Menu Parameter Description Enable/Disable FRB-2 timer (POST timer). FRB-2 Timer Options available: Enabled, Disabled. Default setting is Enabled. FRB-2 Timer Configures the FRB2 Timer timeout. The value is between 1 to 30 minutes. (Note1) timeout Default setting is 6 minutes. Configures the FRB2 Timer policy.
  • Page 92 Parameter Description System Event Log Press [Enter] to configure advanced items. View FRU Press [Enter] to view the FRU information. Information BMC VLAN Press [Enter] to configure advanced items. Configuration BMC network Press [Enter] to configure advanced items. Configuration IPv6 BMC Network Press [Enter] to configure advanced items.
  • Page 93: System Event Log

    5-4-1 System Event Log Parameter Description Enabling / Disabling Options Change this item to enable or disable all features of System Event SEL Components Logging during boot. Options available: Enabled, Disabled. Default setting is Enabled. Erasing Settings Choose options for erasing SEL. Options available: No, Erase SEL Yes, On next reset,...
  • Page 94: View Fru Information

    5-4-2 View FRU Information The FRU page is a simple display page for basic system ID information, as well as System product information. Items on this window are non-configurable. (Note) The model name will vary depends on the product you purchased BIOS Setup - 94 -...
  • Page 95: Bmc Vlan Configuration

    5-4-3 BMC VLAN Configuration Description Parameter BMC VLAN Configuration Select to configure BMC VLAN ID. The valid range is from 0 to 4094. When BMC VLAN ID set to 0, BMC VLAN ID will be disabled. Select to configure BMC VLAN Priority. The valid range is from 0 to 7. BMC VLAN Priority When BMC VLAN ID is set to 0, BMC VLAN Priority will not be selected.
  • Page 96: Bmc Network Configuration

    5-4-4 BMC Network Configuration Parameter Description BMC network configuration Select NCSI and Dedicated Options available: Do Nothing, Model1(Dedicated), Model2(NCSI), Mode3(Failover). Default setting is Do Nothing. Lan Channel 1 Selects to configure LAN channel parameters statically or dynamically (DHCP). Configuration Address source Options available: Unspecified, Static, DynamicBmcDhcp.
  • Page 97: Ipv6 Bmc Network Configuration

    5-4-5 IPv6 BMC Network Configuration Parameter Description IPv6 BMC network configuration IPv6 BMC Lan Channel 1 Enable/Disable IPv6 BMC LAN channel function. When this item is disabled, the system will not modify any BMC network during BIOS IPv6 BMC Lan Option phase.
  • Page 98: Security Menu

    Security Menu The Security menu allows you to safeguard and protect the system from unauthorized use by setting up access passwords. There are two types of passwords that you can set: • Administrator Password Entering this password will allow the user to access and change all settings in the Setup Utility. •...
  • Page 99: Secure Boot

    5-5-1 Secure Boot The Secure Boot submenu is applicable when your device is installed the Windows 8 (or above) operating ® system. Parameter Description System Mode Displays if the system is in User mode or Setup mode. Enable/ Disable the Secure Boot function. Secure Boot Options available: Enabled, Disabled.
  • Page 100 Parameter Description Press [Enter] to configure advanced items. Please note that this item is configurable when Secure Boot Mode is set to Custom. Factory Key Provision Š – Allows to provision factory default Secure Boot keys when system is in Setup Mode.
  • Page 101 Parameter Description Authorized TimeStamps (DBT) Š – Displays the current status of the Authorized TimeStamps Database. – Press [Enter] to configure a new DBT or load additional DBT from storage devices. Key Management – Options available: Update, Append. (continued) OsRecovery Signatures Š...
  • Page 102: Boot Menu

    Boot Menu The Boot menu allows you to set the drive priority during system boot-up. BIOS setup will display an error message if the legacy drive(s) specified is not bootable. Parameter Description Boot Configuration Number of seconds to wait for setup activation key. 65535 (0xFFFF) Setup Prompt Timeout means indefinite waiting.
  • Page 103 Parameter Description FIXED BOOT ORDER Priorities Press [Enter] to configure the boot order priority. By default, the server searches for boot devices in the following sequence: Hard drive. Boot Option #1 / #2 / #3 / #4 / #5 CD-COM/DVD drive. USB device.
  • Page 104: Save & Exit Menu

    Save & Exit Menu The Save & Exit menu displays the various options to quit from the BIOS setup. Highlight any of the exit options then press <Enter>. Parameter Description Save Options Saves changes made and closes the BIOS setup. Save and Exit Options available: Yes, No.
  • Page 105 Parameter Description Loads the default settings for all BIOS setup parameters. Setup Defaults are quite demanding in terms of resources consumption. If you are using low-speed memory chips or other kinds of low-performance components Restore Defaults and you choose to load these settings, the system might not function properly.
  • Page 106: Bios Recovery

    BIOS Recovery The system has an embedded recovery technique. In the event that the BIOS becomes corrupt the boot block can be used to restore the BIOS to a working state. To restore your BIOS, please follow the instructions listed below: Recovery Instruction: 1.
  • Page 107: Bios Post Beep Code (Ami Standard)

    BIOS POST Beep code (AMI standard) 5-9-1 PEI Beep Codes # of Beeps Description Memory not Installed. Memory was installed twice (InstallPeiMemory routine in PEI Core called twice) Recovery started DXEIPL was not found DXE Core Firmware Volume was not found Recovery failed S3 Resume failed Reset PPI is not available...

Table of Contents