LG DLGX7 1 E Series Owner's Manual page 33

Hide thumbs Also See for DLGX7 1 E Series:
Table of Contents

Advertisement

performed to alert you to any serious problems in
the exhaust system of your home.
• Your appliance features Flow Sense
innovative sensing system that automatically
detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint
buildup and free of restrictions allows clothes to
dry faster and reduces energy use.
NOTE
• The appliance should be cool before starting this
test. If the appliance was warmed up during
installation, run the Air Dry cycle for a few
minutes to reduce the interior temperature.
Activating the Installation Test
1
Remove the drying rack and literature, and
then close the door.
• Do not load anything in the drum for this
test, as it may affect the accuracy of the
results.
2
Press and hold the Temp. and Signal buttons
and then press the Power button.
Press and hold the Temp. and Wrinkle Care
buttons and then press the Power button.
(DLE7**0* / DLG7**1*)
• This button sequence activates the
installation test. The code
display if the activation is successful.
TM
, an
3
4
5
or
will
1Ns
1N
Check the Duct Condition
If the Flow Sense
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
• When the appliance is first installed, this test
Press the Start/Pause button.
• The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
Check the display for results.
• During the test cycle, monitor the Flow
TM
Sense
display on the control panel. If no
bars are displayed (or LED is not turned on),
when the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the display will show four bars.
Have the system checked immediately, as
performance will be poor. Other problems
may also be shown with error codes. Refer
to the the Error Code table for details and
solutions.
End of cycle.
• At the end of the test cycle,
display. The test cycle will end and the
appliance will shut off automatically after a
short delay.
TM
LED is turned on, check the
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
INSTALLATION
33
or
will
ENd
O

Advertisement

Table of Contents
loading