Available languages

holes. Clogged holes can cause
unsatisfactory washing results.
The ceiling spray arm is placed on the ceiling
of the appliance. The spray arm (C) is
installed in the delivery tube (A) with the
mounting element (B).
1. Move the upper basket to the lowest level
to reach the spray arm more easily.
2. To detach the spray arm (C) from the
delivery tube (A), turn the mounting
element (B) counterclockwise and pull the
spray arm downwards.

12. TROUBLESHOOTING

WARNING!
Improper repair of the appliance may
pose a danger to the safety of the user.
Any repairs must be performed by
qualified personnel.
The majority of problems that may occur
can be solved without the need to contact
an Authorised Service Centre.
Problem and alarm code
You cannot activate the appliance.
The programme does not start.
3. Wash the spray arm under running water.
C
B
A
4. To install the spray arm (C) back, insert
Refer to the below table for information on
possible problems.
With some problems, the display shows an
alarm code.
Possible cause and solution
Make sure that the mains plug is connected to the mains socket.
Make sure that there is no damaged fuse in the fuse box.
Make sure that the appliance door is closed.
Press the start button.
If the delay start is set, cancel the setting or wait for the end of the
countdown.
The appliance recharges the resin inside the water softener. The dura‐
tion of the procedure is approximately 5 minutes.
Use a thin pointed tool, e.g. a toothpick,
to remove particles of soil from the holes.
Run the water through the holes to wash
soil particles away from the inside.
the mounting element (B) in the spray
arm and fix it in the delivery tube (A) by
turning it clockwise. Make sure that the
mounting element locks into place.