8-3-2. Initial (Lock up)
Initial Failure (Lock up when booting)
Re-download SW the phone.
Check the AP Reset
Check the oscillator clock waveforms.
32.768KHz : OSC400.
OSC400 is operating when
phone is not in sleep mode
Change UCP300, U401
Confidential and proprietary-the contents in this service guide subject to change without prior notice.
Distribution, transmission, or infringement of any content or data from this document without Samsung's written authorization is strictly prohibited.
Download success
RESET_INn
(R340 or R339)
Yes
Normal
Abnormal
Change PBA
END
If Phone do not go download mode, boot code area
No
of EMMC is damaged.
It need to change the UME300(EMMC)
No
Change the UCP300 / change the PBA
Check the OSC400.
(Crack, open etc.)
Check the output clock waveforms and frequency.
※ Test condition (Oscilloscope setting)
: 20.0us.div (time division) @ 32.768Khz
Abnormal