Software update menu will pop up when press confirm key, then select "Yes" to confirm:
The process of software updating:
Method 2:Keep pressing VOL+ and CH+ keys on the machine panel, power on the machine, the standby light flashes quickly after
about 5 seconds, standby light extinguish and turn into lighting after about a minute, means that the upgrade is completed.
5.1.4 Notice:
①. When the machine Upgrading (U disk light flash), do not remove U disk or switch off the power, otherwise it will
destroy the software and lead can not upgrade.
②. The machine must be power off when inserted or pulled out U disk, to avoid U disk or damage the machine.
5.2
Panel Code
Press the following key sequence on a standard RC transmitter: "1999" directly followed by MENU, can see the panel type
information from factory menu, see the Panel PN from the configuration table
CTN_ALT BOM#
32PHT4012/05
Panel Type
K320WDK3B-LW330A2
12
Panel PN
7422320LGK3AK011-F