The K-600D requires no external power supply and provides a floating 600 ohm
audio output. Auxiliary N.O./N.C. relay contacts are provided in cadence with
the ring signal for muting, switching or operation of external signaling devices.
Volume and tone controls are also provided.
Features
• Provides tone over existing paging amplifiers
• Auxiliary relay contacts provided
• Connects directly to ringing analog PABX/KSU
stations
• Floating 600 ohm output
Sales...(715) 386 - 8861
Made in the U.S.A.
Telecommunication Peripheral Products
Provide Night Bell Over your
Existing Paging Amplifier
http://www.VikingElectronics.com
E-mail...Sales@VikingElectronics.
The K-600D eliminates the installation
of multiple bells, relays and power
supplies, whenever night bells, loud
ringing or emergency tones are
required.
The K-600D provides an
existing paging amplifier with a pleasant
electronic warble tone each time it
receives ring voltage from an analog
PABX/KSU extension.
Applications
• Night bell over paging
• Loud ringing over paging
• Contact closure on ringing

Specifications

Ring Voltage: 60V AC minimum, 15Hz - 70Hz
Dimensions: 133mm x 89mm x 44mm (5.25" x 3.5" x 1.75")
Shipping Weight: 1.36 kg (3 lbs.)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-
condensing humidity
Output: Floating 600 ohm , less than .5 VPP
Connections: (1) RJ11 jack and 5 position screw terminal strip
Maximum Cable Run: 15.24m (50 ft)
Relay Contact Ratings: .5A @ 125V AC/1A @ 30V DC