Summary of Contents for Pyramid SIMPLE SMART TIMETRAX Sync

  • Page 2 The information contained herein is subject to change without notice. The only warranties for Pyramid are set forth in the express warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    TimeTrax™ Sync Clock System Quick Start Guide TABLE OF CONTENTS PRODUCT OVERVIEW SYSTEM REQUIREMENTS TRANSMITTERS INSTALLATION PYRAMID WIRELESS RF TRANSMITTER PORTS BELL TONE SYSTEM SOFTWARE SET UP NAVIGATE TO BELL SCHEDULE SPECIFICATIONS SAFETY ANALOG CLOCKS DIGITAL CLOCKS ACCESSORIES WARRANTY & TECHNICAL SUPPORT pyramidtimesystems.com...
  • Page 4: Product Overview

    Analog Digital Clocks Clocks The Pyramid Wireless RF Transmitter controls BCD signals via auxiliary ports: Analog Wire Bell/Tone DIG 4B/DIG 6B 5200 Clock Systems Wired Clocks (8)
  • Page 5: Transmitters

    902MHz-928MHz (128 signaling channels) every 20 seconds), to an unlimited number of clocks. TT Sync software synchronizes PoE clocks & enables Pyramid transmitters to be designated time source for TimeTrax™ Sync Clock & Tone Systems. Wireless RF Secondary Transmitter(s) may be added for additional coverage Dependent upon building Structure pyramidtimesystems.com...
  • Page 6: Installation

    TimeTrax™ Sync Clock System Quick Start Guide WIRELESS RF TRANSMITTER INSTALLATION Choose appropriate location to install 9T1W1 Wireless RF Transmitter. Locate within 50ft cable GPS Time Source reach 250,000 sq ft or less Locate centrally 250,000 SQ FT Contact customer support More than 250,000 sq ft 250,000 SQ FT @ 888.479.7264 ext 1...
  • Page 7: Pyramid Wireless Rf Transmitter Ports

    TimeTrax™ Sync Clock System Quick Start Guide Pyramid Wireless RF Transmitter Ports back view POWER GPS ETHERNET CONNECT Power CONNECT Ether- CONNECT Tone CONNECT Supply (included) net port to PC or System, legacy #42328 GPS network wired BCD clocks Receiver when...
  • Page 8: Software Set Up

    TimeTrax™ Sync Clock System Quick Start Guide SET UP SOFTWARE Contact Pyramid Time Systems for software access via download at: Phone: 888.479.7264 Ext. 267 or Ext. 802 Email: WirelessSales@ptitime.com Install TimeTrax Sync™ Software into a networked computer or one that is...
  • Page 9: Navigate To Bell Schedule

    TimeTrax™ Sync Clock System Quick Start Guide TIME ZONE; DAYLIGHT SAVINGS TIME; TIME SOURCE; REFRESH INTERVAL AT GLOBAL SETTINGS NTP Time Source (MAX 3);Time Zone & Daylight Savings Time will automatically default to Eastern Standard Time. To change global settings, follow these steps: Click on Edit Global Setting Tab.Press enter to confirm.
  • Page 10: Specifications

    -Sends BCD signals to TimeTrax™ analog & digital clocks BCD out/AUX (wired) -Sends BCD signals to Pyramid Tone Systems OPTIONAL GPS PORT (RJ45 COMPATIBLE FEMALE CONNECTOR) : 4800 Baud I/O to receive NMEA time and 1 second edge sync IEC RS232 Compatible...
  • Page 11: Safety

    TimeTrax™ Sync Clock System Quick Start Guide ENVIRONMENTAL : INDOOR USE ONLY Storage Temp -30°C to 80°C, 22°F to 176°F Operating Temp 0°C to 70° , 32°F to 158°F Condensing 95% RH non-condensing SAFETY Do not place transmitter in close proximity of life support systems or critical safety systems.
  • Page 12: Analog Clocks

    TimeTrax™ Sync Clock System Quick Start Guide ANALOG CLOCKS Complete Transmitter installation and/or software set-up prior to clock installation Choose appropriate location to install clock(s). Locate indoors in dry location unless using weather cover (see p.11) Wired clock(s) should be hardwired to standard electrical box by qualified electrician.
  • Page 13: Digital Clocks

    TimeTrax™ Sync Clock System Quick Start Guide DIGITAL CLOCKS Complete Transmitter installation & software set-up prior to clock installation. Choose appropriate location to install clock(s). Locate indoors in dry location unless using weather cover (see p.11) Wired clock(s) should be hardwired to standard electrical box by qualified electrician.
  • Page 14: Accessories

    TimeTrax™ Sync Clock System Quick Start Guide ACCESSORIES PART# ITEM DESCRIPTION 42337 Wall, Secondary Transmitter (without software) S9DSX0LAUB Shelf, Secondary Transmitter (without software) 42328 Receiver, GPS Signal 41269 BCD Extension Cable, 50ft 41314 BCD Extension Cable, 100ft 41313 BCD In-line Cable Coupler Wire Guard Kit, Chrome, 13in Analog 43193-1 Wire Guard Kit, Chrome, 17in Analog...
  • Page 15: Warranty & Technical Support

    The manufacturer’s responsibility under this Warranty is limited to repair or replacement of defective part or parts. Pyramid reserves the right to determine whether parts failed because of defective material, workmanship, or other causes. Failure caused by accident, alteration, misuse or improper packaging of returned unit is not covered by this Warranty.
  • Page 16 • Automatic Adjustment Automatically adjusts for Daylight Savings Time & power outages. • Scheduling Schedule bell/tone systems with the click of a mouse. pyramidtimesystems.com © 2011 Pyramid Time Systems, LLC. All Rights Reserved. 9T1WI WARRANTY & TECHNICAL SUPPORT 888.479.7264...
  • Page 17 TimeTrax™ Sync Clock System Quick Start Guide 3500ss/3600ss/3700ss User Guide Resources: pyramidtimesystems.com For more information, visit for digital guide copies, support resources, and accessories. *When printing off copies of user guides for templates, please open in Adobe Acrobat and follow the following print options: Size: Actual (Measure template for accuracy before using when printing) Booklet (If printing just the template page, make sure it is set to...
  • Page 18 Quick Start Guide CONTACT US: For more information, visit pyramidtimesystems.com or call our technical support team at 888.479.7264 during regular business hours: 8:30am-5pm EST, Monday-Friday. Copyright © 2021 Pyramid Time Systems, LLC. All rights reserved. I2227 Rev F SPECIFICATIONS 888.479.7264...

Table of Contents