Teaching the code

Adam is without code in its factory setting mode and need to be programmed with the code from
an Eva (General or Unique coded). The code of the first Eva detected by the Adam is automatically
programmed as soon as Eva is within the detection distance. If Adam is programmed to accept an
Eva with a general code, it will accept all Eva units with a general code. If it is programmed to
accept an Eva with unique code, it will only accept the unique code of that specific Eva.
Note that it is possible to teach more than one Adam unit to accept the same Eva unit. This is for
example applicable on a sliding door or for machine positioning.

Programming a new Adam without code, to accept a new Eva

1.
Bring the Eva in the range of Adam.
2. Connect the Adam without code to the power supply.
3. The LED on Adam will turn green when the programming procedure is finished.
Note! The programming procedure is taking place only at startup of Adam. Eva must be in range at
this time.
Note! If the teaching procedure fails, and no Eva code is programmed, Adam enters a fail-safe
mode and its red LED starts flashing fast. Erase the code, cycle the power and restart the teaching
code procedure.
Note! The Eva must not be removed during the teaching procedure.

Erasing existing codes from Adam M12-5

1.
Remove Eva from Adam's detection range.
2. Disconnect the power supply on pin 1 on the Adam unit.
3. Connect +24 VDC to pin 2 and 4.
4. Connect the power supply on pin 1 on the Adam unit.
5. After 5-10 sec the light turns green, then immediately disconnect pin 2 and 4 from +24 VDC.
6. The Adam unit will now be reset, and its LED will flash red.
7. Follow normal installation procedure to install Adam again.
Note! If the pin 2 and 4 on the Adam unit is not disconnected from +24 VDC within 5-10 seconds,
Adam enters the fail-safe mode and the red LED starts flashing fast. It is then necessary to restart
the procedure from the beginning.