Do not use an extension cord unless it is absolutely necessary.
Use of improper extension cord could result in risk of fire,electric shock,
or electrocution.
Do not place any object on top of charger or place the charger on
a soft surface that might block the ventilation slots and result in
excessive internal heat. Place the charger in a position away from any
heat source. The charger is ventilated through slots in the top and the
bottom of the housing.
Do not operate charger with damaged cord or plug—have them
replaced immediately.
Do not operate charger if it has received a sharp blow, been
dropped, or otherwise damaged in any way. Take it to an authorised
service centre.
Do not disassemble charger; take it to an authorised service centre
when service or repair is required. Incorrect reassembly may result in a
risk of electric shock, electrocution or fire.
In case of damaged power supply cord the supply cord must be replaced
immediately by the manufacturer, its service agent or similar qualified
person to prevent any hazard.
Disconnect the charger from the outlet before attempting any
cleaning. This will reduce the risk of electric shock. Removing the
battery pack will not reduce this risk.
NEVER attempt to connect two chargers together.
The charger is designed to operate on standard 230V household
electrical power. Do not attempt to use it on any other voltage. This
does not apply to the vehicular charger.
Charging a Battery (Fig. C)
1. Plug the charger into an appropriate outlet before inserting
battery pack.
2. Insert the battery pack
into the charger, making sure the battery
 27 
pack is fully seated in the charger. The red (charging) light will blink
repeatedly indicating that the charging process has started.
3. The completion of charge will be indicated by the red light remaining
ON continuously. The battery pack is fully charged and may be used
at this time or left in the charger. To remove the battery pack from the
charger, push the battery release button
nOTE: To ensure maximum performance and life of lithium-ion battery
packs, charge the battery pack fully before first use.
Charger Operation
Refer to the indicators below for the charge status of the battery pack.
Charge Indicators
Charging
Fully Charged
Hot/Cold Pack Delay*
* The red light will continue to blink, but a yellow indicator light will be
illuminated during this operation. Once the battery pack has reached an
appropriate temperature, the yellow light will turn off and the charger will
resume the charging procedure.
The compatible charger(S) will not charge a faulty battery pack. The charger
will indicate faulty battery by refusing to light or by displaying problem
pack or charger blink pattern.
nOTE: This could also mean a problem with a charger.
If the charger indicates a problem, take the charger and battery pack to be
tested at an authorised service centre.
hot/cold Pack Delay
When the charger detects a battery pack that is too hot or too cold, it
automatically starts a Hot/Cold Pack Delay, suspending charging until the
battery pack has reached an appropriate temperature. The charger then
30
 28 
on the battery pack.
automatically switches to the pack charging mode. This feature ensures
maximum battery pack life.
A cold battery pack will charge at a slower rate than a warm battery pack.
The battery pack will charge at that slower rate throughout the entire
charging cycle and will not return to maximum charge rate even if the
battery pack warms.
The DCB118 charger is equipped with an internal fan designed to cool
the battery pack. The fan will turn on automatically when the battery pack
needs to be cooled. Never operate the charger if the fan does not operate
properly or if ventilation slots are blocked. Do not permit foreign objects to
enter the interior of the charger.
Electronic Protection system
XR Li-Ion tools are designed with an Electronic Protection System
that will protect the battery pack against overloading, overheating or
deep discharge.
The tool will automatically turn off if the Electronic Protection System
engages. If this occurs, place the lithium-ion battery pack on the charger
until it is fully charged.
Wall Mounting
These chargers are designed to be wall mountable or to sit upright on a
table or work surface. If wall mounting, locate the charger within reach of an
electrical outlet, and away from a corner or other obstructions which may
impede air flow. Use the back of the charger as a template for the location
of the mounting screws on the wall. Mount the charger securely using
drywall screws (purchased separately) at least 25.4 mm long with a screw
head diameter of 7–9 mm, screwed into wood to an optimal depth leaving
approximately 5.5 mm of the screw exposed. Align the slots on the back of
the charger with the exposed screws and fully engage them in the slots.
Charger Cleaning Instructions

WARNING: Shock hazard. Disconnect the charger from the AC
outlet before cleaning. Dirt and grease may be removed from the
exterior of the charger using a cloth or soft non-metallic brush. Do not
use water or any cleaning solutions. Never let any liquid get inside the
tool; never immerse any part of the tool into a liquid.
Battery Packs
Important Safety Instructions for All Battery Packs
When ordering replacement battery packs, be sure to include catalog
number and voltage.
The battery pack is not fully charged out of the carton. Before using the
battery pack and charger, read the safety instructions below. Then follow
charging procedures outlined.
READ ALL INSTRUCTIONS
Do not charge or use battery in explosive atmospheres, such as
in the presence of flammable liquids, gases or dust. Inserting or
removing the battery from the charger may ignite the dust or fumes.
Never force battery pack into charger. Do not modify battery pack
in any way to fit into a non-compatible charger as battery pack
may rupture causing serious personal injury.
Charge the battery packs only in D
DO NOT splash or immerse in water or other liquids.
Do not store or use the tool and battery pack in locations where the
temperature may reach or exceed 40 ˚C (104 ˚F) (such as outside
sheds or metal buildings in summer).
Do not incinerate the battery pack even if it is severely damaged
or is completely worn out. The battery pack can explode in a fire.
Toxic fumes and materials are created when lithium-ion battery packs
are burned.
If battery contents come into contact with the skin, immediately
wash area with mild soap and water. If battery liquid gets into the
eye, rinse water over the open eye for 15 minutes or until irritation ceases.