MAINTENANCE
SWING GEAR MANUFACTURED BY
"SIEBENHAAR"
Legend for illustration Z24091
(A)
Position of oil level gauge for checking the oil levels
(1)
Swing gear (RH and LH)
(2)
Brake housing
(3)
Compensator oil tank for swing gear
(4)
Oil level gauge for swing gear
(5)
Oil drain plug for motor adapter housing
(6)
Oil level gauge for motor adapter housing
(7)
Breather filter for brake housing
(8)
Oil level gauge for brake housing
(9)
Oil drain plug for brake housing
(10)
Breather filter
(11)
Drain coupling or evacuation nozzle for Wiggins sys-
tem
SWING GEAR - CHANGE OIL (SIEBENHAAR)
1. Use adequate working platform for draining the oil. Place
receptacles of sufficient capacity (approx. 100 liter) below
each drain coupling (11). Attach drain hose (part of tool set) to
drain coupling (11). Remove parts (4 and 10) to speed up
draining.
2. Clean breather filter (10) with compressed air from inside to
outside and re-install.
3. After the oil is completely drained, flush the gear with the reg-
ular gear oil.
4. Remove drain hose from coupling (11) and attach the protec-
tion cap onto the drain coupling.
5. Fill gear housing through filler opening up to the "MAX" mark
on level gauge (4) with fresh gear oil and re-install oil filler
plug.
NOTICE
For checking the oil level insert the level gauge (4) but
DO NOT screw in, see detail (A).
6. After short operating period check oil level and housings for
leaks.
4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR