Electrical Block Checking - Sony CDP-C435 Service Manual

Compact disc player
Table of Contents

Advertisement

SECTION
3
ELECTRICAL BLOCK CHECKING
Note:
1,
CD Block basically constructed
to operate with-
out adjustment.
Therefore,
check
each
item
in
order given.
2.
Use YEDS-18 disc (3-702-101-01) unless otherwise
indicated.
3.
Use the oscilloscope
with more
than
1OM?2
im-
pedance.
4.
Clean an object lens by an applicator with neutral
detergent
when
the
signal
level
is low
than
specified value with the following checks.
S Curve Check
oscilloscope
BD
board
ee
©
TP (FEO)
O——-o>
TP(VC)
ow—to-
Procedure :
1.
Connect oscilloscope to test point TP (FE) on
BD
board.
2.
Connect between test point TP (FE1) and TP
(VC) by lead wire
3.
Turned Power switch on and actuate the focus
serch. (actuate the focus serch when disc table is
moving in and out.)
4.
Check
the oscilloscope
waveform
(S curve)
is
symmetrical between A and B. And confirm peak
to peak level within 341Vp-p.
within
3£1Vp-p
5.
After check, remove
the lead wire connected
in
step 2.
Note:
* Try to mesure
several
times
to make
sure
that the ratio of
A: B or B:A
is more than
10: 7.
- Take sweep time as long as possible and light
up the brightness to obtain best waveform.
RF Level Check
oscilloscope
BD
board
of
TP (RFO)O——,0+
TP (VC) O=t—0 -
Procedure:
1.
Connect
oscilloscope
to test point TP
(RFO)
on
BD. board.
Turn Power switch on.
Put disc (YEDS-18) in and playback.
Confirm
that oscilloscope
waveform
is clear and
me
Ww bo
check RF signal level is correct or not.
Note:
Clear RF signal waveform means that the shape "©"
can be clearly distinguished at the center of the wave-
form.
VOLT/DIV
:200mV
RF signal waveform
TIME/DIV :500nS
\\4 Wy)
WA
E-F Balance Check
oscilloscope
BD
board
ees
TP (TE)
TP (VC)
Ot
— OF
O—t——0 -
Procedure:
1.
Connect test point TP (ADJ) on Main board to ground and TP
(TE1) to TP (VC) on BD board with lead wire.
2.
Connect
oscilloscope
to test point TP (TE) on
BD
board.
3.
Turn Power switch on.
4,
Put disc (YEDS-18) in and playback.
5.
Confirm
that the osilloscope
waveform
is sym-
metrical on the top and bottom in relation to OV,
and check this level.
Traverse oscilloscope
symmetry
level: 2£1Vp-p
6.
Remove the lead wire connected in step 1.

Advertisement