Miscellaneous Materials - Teac TD-35 Operation Manual

Digital strain indicator
Table of Contents

Advertisement

 
        3. AD ERR 
        4. CAL ERR 
        5. ROM WERR  :ROM write failure.  
        6. ROM RERR  :ROM read failure.  
        7. ROM EERR  :ROM erase failure.  
        8. SYS ERR 
        9. BAD CALD  :Calibration failure due to the abnormal ROM data.  
 
 
 

8. Miscellaneous Materials

 
ZERO adjustment of strain gauge sensor 
 
The sensor generates a slight voltage even if no load is applied.  
When there is a tare weight such as a weight measuring device, the voltage equivalent 
to the tare weight is generated. The zero adjustment range of TD‑35 is ±5mV/V (±
−6
10000×10
  strain). In case it does not meet the zero adjustment within this range, 
as shown in the figure below, the zero point shift resister that corresponds to the 
sensor output can be externally connected so that the zero point is shifted 
electrically. 
 
RZ is connected to only one side depending on the direction of the sensor. The direction 
of zero shift changes depending on the connection either between ‑SIG(B) and +EXC(A) 
or ‑SIG(B) and ‑EXC(C). The RZ is to be connected between ‑SIG and +EXC(B‑A) when the 
imbalance needs to be canceled such as in subtracting tare weight of measuring weight 
devices (tare weight appears as positive in sensor output). 
 
 
 
:Communication with internal A/D failed. (Reboot the unit)  
:Invalid written data in ROM.  
:Internal process error.  
15 