4.2. TAMP adjustment
Adjustment Conditions
1) Receive the PAL standard color bar signal.
MODEL
32AX5
Setting value
101 ~ 105
Reference
(Screen of page 1 of adjustment process menu DVP hierarchy)
0
1
2
3
4
D V P
1
0
T A M
1
Y D A
2
T A M
3
N T S
4
P A L
5
S E
C A M
6
7
8
9
10
11
12
13
14
15
5
6
7
8
9
10
11
P
1 L
T
A
P
1 H
C
T A M P 1
T A M P 1
T A M P 1
Adjustment Procedure
1) If the maximum value of "PAL TAMP1" on page 1 of adjustment pro-
cess DVP hierarchy is not in the range of values in the list below,
adjust "PAL TAMP1" on the same page so that the maximum value of
"Y" is in the range of values in the list below.
* Note that the setting value may vary by model.
2) When pressing the TAMP1 direct keys, adjustment of "PAL TAMP1"
is complete.
Then, The values of "NTSC TAMP1" and "SECAM TAMP1" are auto-
matically set.
(NTSC: Value of PAL –7, SECAM: The same value as PAL)