Electrical Adjustment Instructions - Sylvania SC309D Service Manual

9" color tv/vcr combination
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note:
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White Win-
dow, Red Color, Dot Pattern, Gray Scale, Mono-
scope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (FL8A, FL8N), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
How to make service remote control
unit:
1. Prepare remote control unit. (Part No. N0107UD or
N0150UD)
Remove 3 screws from the back lid. (Fig. 1-1)
SCREW
Remote control unit (Bottom)
2. Remote control unit: Part No. N0107UD
Add J1 (Jumper Wire) to the remote control CBA.
(Fig. 1-2)
Remote control CBA
Remote control CBA
Remote control unit: Part No. N0150UD
Cut off pin 10 of the remote control microprocessor
and short circuit pins 10 and 17 of the microproces-
sor with a jumper wire.
Note: The attached remote control unit can not be
used as service remote control unit.
How to Set up the Service mode:
Service Mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press " WAKE-UP/SLEEP " button on the service
remote control unit.
1a. DC 117V (+B) Adjustment
(AC Power)
Purpose: To obtain correct operation.
Symptom of Misadjustment: The picture is dark and
unit does not operate correctly.
Test point
TP601
(+B)
TP602
(GND)
Tape
---
Note: TP601(+B), TP602(GND), VR601 --- Main CBA
1. Connect the unit to AC Power Outlet.
2. Connect DC Volt Meter to TP601(+B) and
TP602(GND).
3. Adjust VR601 so that the voltage of TP601(+B)
becomes +117±0.5V DC.
Fig. 1-1
Fig. 1-2
Fig. 1-2
1-7-1
Adj. Point
Mode
VR601
---
M. EQ.
DC Voltmeter
+117±0.5V DC
Plastic Tip Driver
Input
-----
Spec.
T4403EA